T1/E1 port and DS0 selection
219
Models 2616RC, 3096RC & 3196RC Admin Reference Guide
14 • PPP
Figure 120. WAN Circuit Configuration Link window
2.
Click on
Channel Assignment
link (see
figure 120
) to access the
WAN Circuit Channel Assignment
window
(see
figure 121
). Options for the T1/E1 DS0s displayed on this page are:
– clear(9). The T/E1 DS0s carry user data (default)
– framerelay(3). The selected DS0(s) will carry management data using Frame Relay.
– ppp(5). The selected DS0(s) will carry management data using PPP
Figure 121. WAN Circuit Channel Assignment window displaying PPP configuration