6-8
Safe Torque Off
AC30V series Variable Speed Drive
STO Technical Specification
INPUTS SPECIFICATION
STO A Input and STO B Input comply with IEC61131-2. Note: inputs do not have hysteresis.
Recommended input voltage for low level:
0V to +5V
Recommended input voltage for high level:
+21.6V to +26.4V
Typical input threshold voltage:
+10.5V
Indeterminate input range:
+5V to +15V. Function is undefined.
Absolute maximum input voltage:
-30V to +30V
Typical input current @ 24V
9mA
Fault detection time
:
2.3sec typical;
< 1.6sec will not generate a fault
> 3.0sec will generate a fault.
3
A fault is defined in this context as STO A Input and STO B Input being sensed in opposite logic states.
Summary of Contents for AC30V Series
Page 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Page 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Page 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Page 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Page 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Page 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Page 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Page 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Page 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Page 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Page 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...