10-6
Trips & Fault Finding
AC30V series Variable Speed Drive
Runtime Alerts
A Runtime Alert is a fault that indicates a permanent hardware error. The Runtime Alert display is of the form
RUNTIME ALERT
CODE 00000000
CODE is a number in the range 0 to 65000. The following value is used to provide additional information to assist Parker Hannifin Technical
Support personnel.
CODE
ERROR
Possible Reason for Error
1 to
255
Internal exception
•
VCM not secured to power stack
•
Option not secured correctly to VCM control card
•
Earth bonding failure.
•
Fault during firmware upgrade
1001
to
1003
Processor overload
•
Select a lower switching frequency, (
Parameters::Motor Control::Pattern Generator::Stack Frequency)
•
Record the error message and contact Technical Support
1006
Memory overflow
•
Reduce the complexity of the application
•
Reduce the number of parameters being accessed via the on board Modbus TCP protocol
•
Reduce the number of parameters being accessed by the fieldbus communications option.
1007
Uninitialized pointer
•
Record the error message and contact Technical Support
1010,
1101
to
1111
Initialization error
•
Record the error message and contact Technical Support
1200
to
1299
Communications option
error
•
Ensure the communications option is correctly fitted
•
Update the firmware in the AC30.
•
Replace the communications option
1300
Ethernet fault
•
Record the error message and contact Technical Support
1301
Modbus server
•
Record the error message and contact Technical Support
1302
HTTP server fault
•
Record the error message and contact Technical Support
Summary of Contents for AC30V Series
Page 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Page 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Page 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Page 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Page 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Page 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Page 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Page 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Page 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Page 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Page 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...