Application ‘3’: Presets
This is ideal for applications requiring multiple discrete speed levels.
The setpoint is selected from either the sum of the analogue inputs, (as in Application 1 and known here as
PRESET 0), or as one of up to seven other pre-defined speed levels. These are selected using DIN2, DIN3
and DIN4, refer to the Truth Table below.
The keypad can be used to re-define the speed levels of the PRESET 1 to PRESET 7 setpoints. Reverse
direction is achieved by entering a negative speed setpoint.
Configuration Setup:
RL1A
110-230 VAC (or 24VDC) voltage supply
RL1B
Healthy:
Relay output (to lamp)
TH1
Motor Thermistor ‘+’ connection
TH2
Motor Thermistor ‘-’ connection
AI1
Remote Setpoint (%)
– input 1:
0-10 V variable input (from potentiometer)
AI2
Remote Setpoint ‘Trim’ (%) – input 2:
4-20 mA variable input (from current source)
AO1
Speed Demand (%):
0-10 V variable output (to voltmeter)
AO2
Value = 100%:
0-10 V variable output (+10 V fixed reference voltage)
DX1
Run Forward:
24 V digital input
DX2
Preset Select 1:
24 V digital input
DX3
Preset Select 2:
24 V digital input
DI4
Preset Select 3:
24 V digital input
DI5
Not Coast Stop:
24 V digital input
STO
STO
DISABLED
(drive operational)
V
↑
V
S