MSG11-5715-743/EN: AC20F Series - Hardware Installation Manual
MSG11-5715-743/EN 24.04.2023
93 (148)
-
Press the ‘
Run
’ key:
Local ‘Run’ Enable
Onboard Keypad Display
6901 Remote Keypad Display
-
The drive will enable and should accelerate the motor to the speed demanded. The ‘
Speed
Percent
’ parameter provides the real time speed feedback (% of motor nameplate rpm) value.
-
When the drive is running, the drive will show the following status indication:
Drive ‘Running’ Indication
Onboard Keypad Display
6901 Remote Keypad Display
‘
RUN
’ LED Illuminates.
If the ‘
REV
’ LED is also illuminated, motor is
running in the reverse direction:
Motor ‘
Running
’ LED Illuminated, motor
‘
Stopped
’ LED off.
The shaft will rotate in the direction indicated by
the direction LEDs:
‘
FWD
’ direction:
‘
REV
’ direction:
4. Stopping The Drive:
To stop the drive:
-
Press the ‘
Stop
’ key:
Local ‘Stop’ Mode Initiation
Onboard Keypad Display
6901 Remote Keypad Display
The drive should decelerate the motor to a standstill, before disabling:
Drive ‘Stopped’ Indication
Onboard Keypad Display
6901 Remote Keypad Display
‘
RUN
’ LED will flash during motor deceleration,
until the motor has come to a stop.
Motor ‘
Stopped
’ LED will flash during motor
deceleration, until the motor has come to a stop,
when the ‘
Stopped
’ LED will illuminate.