4-22
Operating the Drive
DC590+ Series DC Digital Drive
SPEED SETPOINT
TIME-OUT IN NORMAL STOP
0%
START/RUN (C3)
SPEED SETPOINT
SPEED DEMAND
0%
0%
SPEED FEEDBACK
STOP ZERO SPEED
(DEFAULT 2% )
= SPEED SETPOINT
CONTACTOR WILL DROP OUT
IF SPEED FEEDBACK > STOP ZERO SPEED
WHEN STOP LIMIT TIMED OUT
0%
DRIVE ENABLE =ENABLED
DRIVE RUN LED
AND START CONTACTOR
STOP LIMIT ( DEFAULT 60.0 SEC )
DRIVE ENABLE =DISABLED
DRIVE RUN LED & START CONTACTOR
t
t
t
t
Control Signals
Speed Demand
Actual Speed
Indicators
Summary of Contents for 590+ series
Page 2: ......
Page 14: ...Cont 12...
Page 16: ...DC590 Series DC Digital Drive...
Page 20: ......
Page 32: ...2 12 Product Overview DC590 Series DC Digital Drive...
Page 34: ......
Page 130: ...3 96 Installing the Drive DC590 Series DC Digital Drive...
Page 132: ......
Page 164: ...4 32 Operating the Drive DC590 Series DC Digital Drive...
Page 166: ......
Page 174: ...5 8 Control Loops DC590 Series DC Digital Drive...
Page 176: ......
Page 202: ......
Page 222: ...7 20 Trips and Fault Finding DC590 Series DC Digital Drive...
Page 224: ......
Page 242: ......
Page 272: ...DC590 Series DC Digital Drive...
Page 288: ...B 16 Certification DC590 Series DC Digital Drive...
Page 290: ......
Page 342: ...C 52 Parameter Specification Tables DC590 Series DC Digital Drive...
Page 344: ......
Page 365: ...Programming D 21 DC590 Series DC Digital Drive Functional Description...
Page 494: ...D 150 Programming DC590 Series DC Digital Drive Programming Block Diagram Sheet 1...
Page 495: ...Programming D 151 DC590 Series DC Digital Drive Programming Block Diagram Sheet 2...
Page 496: ...D 152 Programming DC590 Series DC Digital Drive Programming Block Diagram Sheet 3...
Page 497: ...Programming D 153 DC590 Series DC Digital Drive Programming Block Diagram Sheet 4...
Page 502: ...D 158 Programming DC590 Series DC Digital Drive...
Page 504: ......
Page 506: ...E 2 Technical Specifications DC590 Series DC Digital Drive...
Page 507: ...Technical Specifications E 3 DC590 Series DC Digital Drive...