The statistics collected by the unit depend upon the device at the far end of the
connection. If the far-end device is a FrameSaver SLV unit, frame relay, latency,
and FDR/DDR (Frame Relay Delivery Ratio [delivered frames/offered frames];
Data Delivery Ratio [delivered octets/offered octets]) performance statistics are
collected. If the far-end device is a non-FrameSaver device, or a FrameSaver 9120
or 9620, only frame relay statistics are collected.
DLCI Performance Statistics
These statistics appear when DLCI is selected from the Performance Statistics
menu.
Main Menu
→
Status
→
Performance Statistics
→
DLCI
This screen only appears when Service Type is set to Frame Relay.
Table 5-13. DLCI Performance Statistics (1 of 2)
Statistic
What It Indicates
DLCI Up Since *
Date and time that the DLCI was last declared Active after a
period of inactivity. Down is displayed if the DLCI is inactive.
If the DLCI was Down, this is the time that the DLCI recovered.
If the DLCI was never Down, this is the first time the unit
discovered that the DLCI was active in the network.
DLCI Up Time *
Days, hours, minutes, and seconds since the DLCI was last
declared Active after a period of inactivity. Down is displayed if
the DLCI is inactive.
If the DLCI was Down, this is the amount of time since the DLCI
recovered.
If the DLCI was never Down, this is the amount of time since the
unit discovered that the DLCI was active in the network.
Total Tx Frames/
Tx Octets
Total number of data frames and octets (8-bit bytes) transmitted
for the selected DLCI on the frame relay link.
Within CIR **
The number of frames and octets sent by the far-end device
for on the selected DLCI of the frame relay link that were
within the committed information rate.
Between
CIR&EIR **
The number of frames and octets sent by the far-end device
on the selected DLCI of the frame relay link that were
between the committed information rate and excess
information rate.
Above EIR **
The number of frames and octets sent by the far-end device
on the selected DLCI of the frame relay link that were above
the excess information rate.
With DE Set
The number of frames and octets sent on the selected DLCI
of the frame relay link with the discard eligible bit set.
* Only appears for the network interface.
** Only appears for units with the FLEX SLV feature set.
Summary of Contents for FrameSaver FLEX 9123
Page 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Page 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Page 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Page 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Page 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Page 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Page 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Page 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Page 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...