6. Troubleshooting
6-18
August 2001
9123-A2-GB20-20
PVC Loopback
The PVC Loopback loops frames back to the selected interface on a per-PVC
basis. This test logically (not physically) loops back frames received from another
FrameSaver device through the selected frame relay PVC to the same
device.
Main Menu
→
Test
→
Network PVC Tests
Main Menu
→
Test
→
Data Port PVC Tests
Send Pattern
This test sends packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another FrameSaver device.
To send a pattern test on a link:
Main Menu
→
Test
→
[Network PVC Tests/Data Port PVC Tests]
If the CIR is zero, the pattern will be sent at a rate of 1000 bps.
98-16186
DTE
Network
PVC #
x
Network PVC Loopback
PVC #
x
PVC #
x
DTE
Network
98-16187
Port PVC Loopback
PVC #
x
If the selected
DLCI is configured as . . . Then . . .
And the default
Rate (Kbps) setting is . . .
Standard
(Disruptive)
appears
after Test
100% of CIR
Multiplexed
(Non-Disruptive)
appears after Test
10% of CIR
Summary of Contents for FrameSaver FLEX 9123
Page 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Page 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Page 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Page 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Page 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Page 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Page 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Page 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Page 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...