3. Configuration
3-38
August 2001
9123-A2-GB20-20
CIR (bps)
Possible Settings: 0 – 1536000
Default Setting: 64000
Determines the data rate for the DLCI that the network commits to accept and carry
without discarding frames; the CIR in bits per second. Entry of an invalid rate causes the
error message
Value Out of Range (0 –
x
)
, where
x = the maximum line rate
available on the port.
0 – 1536000 – Specifies the network-committed data rate.
Tc
Possible Settings: 1 – 65535
Default Setting: Read Only
Displays the DLCI’s calculated value of its committed rate measurement interval (Tc) in
milliseconds. This value is calculated based upon the settings for the Committed Burst
Size Bc (Bits) and CIR (bps) options.
Committed Burst Size Bc (Bits)
Possible Settings: CIR, Other
Default Setting: CIR
Specifies whether the DLCI’s committed burst size will follow the CIR, or whether it will be
entered independently. This value is the maximum amount of data that the service
provider has agreed to accept during the committed rate measurement interval (Tc).
CIR – Uses the value in the CIR (bps) option as the committed burst size (Bc). The Bc
and excess burst size (Be) options are updated when a CIR update is received from the
network switch.
Other – Allows you to specify the committed burst size for the DLCI. When Other is
selected, the Bc and Be values must be manually entered and maintained, as well.
Bc
Possible Settings: 0 – 1536000
Default Setting: 64000
Allows you to display or change the DLCI’s committed burst size.
Display Conditions – This option only appears when Committed Burst Size is set to
Other.
0 – 1536000 – Specifies the DLCI’s committed burst size.
Excess Burst Size (Bits)
Specifies the maximum amount of data in bits that the network may accept beyond the
CIR without discarding frames.
Be
Possible Settings: 0 – 1536000
Default Setting: 1472000
Allows you to display or change the DLCI’s excess burst size.
0 – 1536000 – Specifies the DLCI’s excess burst size.
Table 3-7.
DLCI Record Options (2 of 3)
Summary of Contents for FrameSaver FLEX 9123
Page 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Page 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Page 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Page 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Page 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Page 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Page 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Page 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Page 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...