COMSPHERE 3600 Series Data Service Units
3-8
July 1999
3610-A2-GB91-90
Slide the DSU into the slot, aligning the circuit
card with the rear connector plate until the
connectors seat firmly into the back of the carrier.
Press the faceplate latch to secure the DSU into
the carrier, rotate the circuit pack lock into the
closed position (
Figure 3-3
), and tighten the screw.
6. Return to the rear of the carrier and tighten the
rear connector plate screw.
7. At the rear of the carrier, connect the appropriate
DTE interface cable (EIA-232-D or V.35) to the
rear connector plate. For an EIA-232-D interface
cable, connect the EIA-232-D cable to the top
DTE connector on the rear connector plate.
For the 25-pin V.35 interface, a modular DSU
V.35 adapter was shipped with the unit. To
connect a V.35 adapter to the 25-pin V.35
connector, refer to Figure 3-5 and perform the
following steps:
a. Connect the 25-pin end of the modular DSU
V.35 adapter to the bottom DTE connector of
the rear connector plate. Tighten the
thumbscrews on each side of the connector.
b. Connect the V.35 interface cable to the 34-pin
end of the V.35 adapter, then tighten the
screws on each side of the cable connector.
8. The installed DSU is connected to the DDS
network through the 50-pin connectors on the rear
of the carrier. These interfaces are specified in the
USOC RJ48T, and the pin assignments are shown
in
Appendix F
. Proper network connection to the
DDS facility or to the network channel-
terminating equipment must be made at the far
end of the cable.
9. If the network line and remote DSU are installed
and tested, do a Remote Loopback – a Test Pattern
test.
10. Circuit ID information can be written on the cover
plate under the appropriate slot number.
25-Pin Connector
V.35 Adapter
V.35 Cable
Thumbscrews
99-16298
Figure 3-5. Modular DSU V.35 Adapter Installation
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90...