DSU Operations
4-37
3610-A2-GB91-90
July 1999
Results
The DSU displays the following when the local DSU
transmitter is enabled:
F1
DSU: Enable
Command Complete
F2
F3
When the DSU transmitter is disabled, the following is
possible:
•
Disabled tributaries and the control respond to tests;
aborting a test clears the test but the unit remains
disabled.
•
A tributary or control in test clears the test when a
Disable (or Enable) command is received.
•
If an Enable command is executed to a control from
the NMS or local DCP, all disabled tributaries are
enabled; all tributaries in test are restored to Data
mode.
LEDs
The LEDs selection is only available from the Local
branch. This selection allows you to monitor the port at
any given time. When selected, the port’s lead activity is
reflected in the DCP circuit designation status indicators
(TXD, RXD, etc.) on the faceplate of the Model 3611
DSU, or on the DCP of the Model 3610 DSU.
External Leads
The External Leads (ExtL) selection allows you to
display the state of four general-purpose leads on the
EIA-232-D/V.24 Port 1 interface: Pins 12 and 13 for
output (control leads) and Pins 19 and 23 for input (alarm
leads). If the configuration option External Leads (Ext
Leads) is set to ExtLd, you can change the state of the two
output leads from the DCP or a 6700 or 6800 Series NMS.
If the DSU’s diagnostic protocol is ADp and the CCN by
External Leads (CCN by EL) configuration option has
been enabled, a control DSU reports any changes to the
four leads to the 6700 or 6800 Series NMS as part of its
health and status poll response.
If you have a modular DSU, you can use Paradyne’s
NMS adapter cable (3000-F2-510) to access Pins 12, 13,
19, and 23 to make use of external leads.
To access the External Leads selection from the
top-level menu, make the following selections:
•
Local (F1), or Remot (F2) and Address
•
Ctrl
•
ExtL
The following submenu displays after selecting ExtL:
F1
External Leads:
Displ
Chang
F2
F3
NOTE
For Chang to appear, the Ext
Leads configuration option in the
Gen configuration submenu must
be enabled. Refer to the
General
Configuration Options Table
in
Chapter 6.
Displaying External Leads
The Display (Displ) selection allows you to view the
external lead states. When Display is selected, the
External Leads status report display shows the current
status of the general-purpose external leads on the
EIA-232-D/V.24 interface.
To display the External Leads:
F1
External Leads:
Displ
Chang
F2
F3
The input leads appear (A is Pin 23, B is Pin 19):
F1
External Leads:
In A:
In B:
F2
F3
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90...