Diagnostic Control Panel Messages Reference

C-11

3610-A2-GB91-90

July 1999

Dial Backup Messages

The following messages only appear when a dial

backup module (DBM) is installed. Table C-8 lists the
progress messages that appear when a point-to-point call
is being placed, while 

Table C-9

 lists possible error

messages.

Table C-8

Point-to-Point Dial Backup Progress Messages

Message

Condition

DBM:Answering

DBM is answering an incoming call.

DBM:Callback

Callback sequence initiated.

DBM:Connected

Connected.

DBM:Disabled

No calls can be initiated or answered.

DBM:FoundAnswTon

A 4-wire Switched 56 DBM is answering an incoming call.

DBM:Ringing

Ringing at remote DBM or external dial modem.

DBM:Standby

A connection is made but the digital circuit is still the active link.

DBM:Starting Up

Training for synchronization.

DBM:Wait Callbck

Expecting callback from remote DBM.

DBM:WaitForAnswr

Call placed and waiting for connection.

DBM:WaitForSync

Call placed and waiting for connection (2-wire Switched 56 DBM only).

DBM:xxxxxxxxxxx

The last 11 digits for the telephone number dialed.

Summary of Contents for COMSPHERE 3610

Page 1: ...COMSPHERE 3600 SERIES DATA SERVICE UNITS MODELS 3610 AND 3611 OPERATOR S GUIDE Document No 3610 A2 GB91 90 July 1999...

Page 2: ...eedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne...

Page 3: ...ed service personnel 6 General purpose cables are provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibilit...

Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices...

Page 5: ...ny may discontinue your service temporarily If possible they will notify you in advance But if advance notice is not practical you will be notified as soon as possible You will be advised of your righ...

Page 6: ...ertified connector assembly telephone connection cord The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations If you experience...

Page 7: ...tion Planning 2 2 Hardware Straps 2 3 Model 3610 DSU Installation 2 4 Electrical Connection 2 6 Network Diagnostic Connection 2 8 Async Terminal Connection 2 9 Software Configuration 2 9 DDS or LADS N...

Page 8: ...Branch 4 39 5 Operation Verification Overview 5 1 MCMP Initialization Procedure 5 1 Verification Procedure 5 2 6 Configuration Options Overview 6 1 Option Sets 6 1 Using the DCP to Set Configuration O...

Page 9: ...el 3610 DSU DDS Network Connection 2 10 3 1 Non Modular Model 3611 Circuit Card Switch and Jumper Locations 3 3 3 2 Modular 3611 Circuit Card Switch and Jumper Locations 3 4 3 3 Model 3611 DSU Install...

Page 10: ...alth and Status Display Screen D 18 D 24 Identity Display Screen D 19 E 1 Control Channel E 2 E 2 Extended Control Channel E 3 E 3 Diagnostic Channel E 4 F 1 Digital Network Connector F 2 F 2 3600 Hub...

Page 11: ...15 MCMP Technical Specifications 1 38 1 16 Technical Specifications for Digital Bridge Capability 1 39 2 1 Model 3610 DSU Switch Settings 2 3 2 2 Model 3610 DSU Jumper Straps 2 5 3 1 Model 3611 DSU S...

Page 12: ...tus Messages C 8 C 6 Subnetwork Health and Status Messages C 9 C 7 Multipoint Backup Progress Messages C 10 C 8 Point to Point Dial Backup Progress Messages C 11 C 9 Point to Point Dial Backup Error M...

Page 13: ...and Digital Bridge Options Applications Guide if your application uses a TDM or MCMP circuit card or uses DBM Vs DBM Ss or DBM Ds The SNA Diagnostic Interface option as it applies to these application...

Page 14: ...lement Should more detail about how the DSU operates be required the following additional documentation also may be ordered 3610 A2 GB41 COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 T...

Page 15: ...cal Reference 62310 1987 Bell Canada DCTE Specifications Bell Communications Research Technical Reference Publication 41028 ITU T V 35 ISO 2593 EIA 232 D V 24 ISO 2110 Integrated Network Corporation C...

Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90...

Page 17: ...REr 3600 Series Data Service Units DSUs Models 3610 and 3611 support communication between computers and other data processing devices by providing connections to digital transmission facilities NOTE...

Page 18: ...BM TDM and MCMP features Feature Overview The 3600 Series DSU without any options offers the following features Multispeed operation A 3600 Series DSU operates on the DATAPHONEr Digital Service networ...

Page 19: ...our System Administrator for assistance Async Terminal control A Model 3610 DSU can be controlled from an async asynchronous terminal When this feature is enabled the DSU is operated from the async te...

Page 20: ...h TDM that is configured as an extended or central site bridge The digital bridge essentially bridges multiple point to point LADS circuits into a single front end processor FEP Refer to the COMSPHERE...

Page 21: ...he Async Sync configuration option must be disabled and the synchronous port rate must be set to a rate greater than or equal to four times the asynchronous DTE rate For example select 1 2 kbps for th...

Page 22: ...more bandwidth is available for diagnostics Asynchronous port speeds of 150 300 600 and 1800 bps may be obtained by oversampling oversampling must be used to obtain these port rates Table 1 2 Valid S...

Page 23: ...ion enabled a single port multipoint circuit can operate using nondisruptive diagnostics similar to a single port point to point configuration Figure 1 2 illustrates this configuration Note that both...

Page 24: ...software firmware version is 6 xx otherwise the units should be returned to the factory to be upgraded Contact your authorized service representative to arrange for your upgrade Figure 1 3 shows a co...

Page 25: ...nother device In each combination of equipment the Model 3610 and 3611 DSUs can be either the control or the tributary Table 1 4 Diagnostic Compatibilities Paradyne Device Communicating with Model 361...

Page 26: ...ruptive nondisruptive or mixed communication Refer to the following section In Band Secondary Channel Transport for further information This feature supports up to 80 addresses for a DPII protocol or...

Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2...

Page 28: ...Diagnostics In a nondisruptive diagnostic network diagnostic data is transmitted without interrupting user transmitted data In addition nondisruptive diagnostics allow the control DSU to obtain real...

Page 29: ...y channel protocol The tributary DTEs in a multipoint network are sequentially polled by the control DTE and each tributary responds one at a time with data When a tributary DTE raises RTS no other DT...

Page 30: ...ation using the LinkConfig Link Configuration configuration option as described in Table 6 4 Diagnostic General Configuration Options in Chapter 6 Addressing A Model 3611 DSU has two addresses Physica...

Page 31: ...t 256 addresses on each control channel CC Refer to Table 1 6 When the control DSU is using ADp the range of network addresses is 1 through 255 if the DSU is using DPII the range of network addresses...

Page 32: ...144 10 22 43 63 76 104 109 145 11 23 44 64 77 105 110 146 12 24 45 65 78 106 111 147 13 25 46 66 79 107 112 148 14 26 47 67 80 108 113 151 15 27 48 68 81 111 114 152 16 28 49 71 82 112 115 153 17 31...

Page 33: ...5 227 207 267 239 307 144 188 176 228 208 268 240 308 145 191 177 231 209 271 241 311 146 192 178 232 210 272 242 312 147 193 179 233 211 273 243 313 148 194 180 234 212 274 244 314 149 195 181 235 21...

Page 34: ...2 5 08 200 1 8 38 940 2 6 09 220 1 9 39 960 2 7 10 240 1 10 40 a00 2 8 11 260 1 11 41 a20 2 9 12 300 1 12 42 a40 2 10 13 320 1 13 43 a60 2 11 14 340 1 14 44 b00 2 12 15 360 1 15 45 b20 2 13 16 400 1 1...

Page 35: ...1120 3 5 99 1860 4 3 70 1140 3 6 100 1900 4 4 71 1160 3 7 101 1920 4 5 72 1200 3 8 102 1940 4 6 73 1220 3 9 103 1960 4 7 74 1240 3 10 104 1a00 4 8 75 1260 3 11 105 1a20 4 9 76 1300 3 12 106 1a40 4 10...

Page 36: ...8 2740 5 30 129 2020 5 1 159 2760 5 31 130 2040 5 2 160 2800 N A N A 131 2060 5 3 161 2820 6 1 132 2100 5 4 162 2840 6 2 133 2120 5 5 163 2860 6 3 134 2140 5 6 164 2900 6 4 135 2160 5 7 165 2920 6 5 1...

Page 37: ...f20 6 29 219 3660 7 27 190 2f40 6 30 220 3700 7 28 191 2f60 6 31 221 3720 7 29 192 3000 N A N A 222 3740 7 30 193 3020 7 1 223 3760 7 31 194 3040 7 2 224 3800 N A N A 195 3060 7 3 225 3820 8 1 196 310...

Page 38: ...7 can have tributaries with addresses in the range 1 157 1 to 1 157 79 using DPII protocol and 1 157 1 to 1 157 255 using ADp See Figure 1 5 DCP communications from a control are directed to a tributa...

Page 39: ...aggregate data stream including diagnostics and framing on the alternate V 35 or EIA 232 D interface of Port 1 Aggregate data is then switched or bridged with the data on the DDS line This aggregate...

Page 40: ...mands The 6700 Series NMS software provides a Commands pull down window to access Standby Facility Aggregate switching can also be controlled automatically enabling the Answer External Backup AnswExtB...

Page 41: ...ontrol DBMs to call the remote DSU The 6700 Series NMS software provides a Commands pull down window to access Standby Facility The DSU s timing is taken from the source specified in the AgSw Timing A...

Page 42: ...ot be configured so that the DSR lead is forced on This will force the aggregate switch to be turned on When the remote site is expected to initiate a dial backup session the DSU s Answer External Bac...

Page 43: ...ommands pull down window to access Standby Facility If the external DBU is capable of and configured for DTR disconnect the external DBU drops the call when DTR is turned off at its DTE interface Figu...

Page 44: ...115 Vac 24 Vac CT 60 Hz 3 0 053 amp 8 00 watts at 115 Vac 24 Vac CT 60 Hz 3 0 068 amp 8 60 watts at 115 Vac 24 Vac CT 60 Hz 3 0 076 amp 9 10 watts at 115 Vac 24 Vac CT 60 Hz 3 0 092 amp 12 15 watts a...

Page 45: ...or The adapter provides an interface between the DSU s 25 pin D type connector and the DTE cable s V 35 connector ENVIRONMENT Operating Temperature Storage Temperature Relative Humidity Shock and Vibr...

Page 46: ...9 6 kbps 8 bits per character including 1 stop bit no parity PHYSICAL DIMENSIONS 3610 DSU Height Width Depth 3610 DSU with TDM or MCMP Height Width Depth 3611 DSU modular or non modular Height Width t...

Page 47: ...6 kg 5 4 pounds 2 45 kg 3 4 pounds 1 55 kg 3 6 pounds 1 64 kg 1 1 pounds 0 48 kg 1 5 pounds 0 68 kg 2 0 pounds 0 88 kg 0 9 pound 0 41 kg 1 3 pounds 0 61 kg 0 1 pound 0 06 kg 1 0 pound 0 44 kg PORT RAT...

Page 48: ...s 4 bps 19 2 kbps 5 bps 9 6 kbps 1 bps 4 8 kbps 0 bps 2 4 kbps 0 bps DDS NETWORK INTERFACE 3610 DSU 3611 DSU 8 pin modular jack USOC RJ48S One or two 50 pin connector USOC RJ48T DIAGNOSTIC INTERFACE 3...

Page 49: ...diagnostics 2500 Series 2500 loopbacks Table 1 10 1 of 2 V 32 DBM or DBM V Technical Specifications Specifications Criteria RINGER EQUIVALENCE NUMBER REN DBM option 0 7B APPROVALS DOC Certification Nu...

Page 50: ...ps can be used 1 RECEIVE VF INTERFACE Dynamic Range V 32 2 wire PSTN Impedance 43 to 10 dBm 600 SWITCHED NETWORK INTERFACE 3610 DSU 3611 DSU or DBM V 6 pin modular jack Permissive USOC RJ11C 8 pin mod...

Page 51: ...hange carrier 4 wire switched access DATA RATES 56 kbps Note that the 4 wire Switched 56 DBM or DBM S uses proprietary rate adaption to support data rates of less than 56 kbps DBM COMPATIBILITY If Cal...

Page 52: ...or Callback or Password security then the device is compatible with a 3600 Series Switched 56 DBM only If Call Setup is set for Alarm or None then any Switched 56 kbps terminal interface unit TIU can...

Page 53: ...firmware is Release 6 24 or greater and TDM firmware is Release 5 C or greater 3610 DSU 6 port TDM Provides five additional 25 pin D subminiature connectors for a total of six EIA 232 or V 35 interfa...

Page 54: ...U 6 port MCMP 3610 DSU MCMP DSD 3611 DSU non modular 3611 DSU modular Provides an additional 25 pin D subminiature connector for a total of two EIA 232 or V 35 interfaces that can be set independently...

Page 55: ...SU firmware is Release 6 24 or greater and TDM firmware is Release 5 C or greater Provides five additional 25 pin D subminiature connectors for a for a total of six EIA 232 or V 35 interfaces that can...

Page 56: ...Service Units 1 40 July 1999 3610 A2 GB91 90 Equipment Warranty and Support For the equipment warranty and support instructions refer to Warranty Sales Service and Training Information on Page A in t...

Page 57: ...as a tributary DSU for operation at 9 6 kbps on a point to point circuit The Model 3610 DSU is designed for desktop operation Installation consists of the following procedures which should be performe...

Page 58: ...ted at the data rate for which access to the DDS network is provided In addition the DSU must be connected to the dial network Refer to the notice at the front of this guide to ensure compliance with...

Page 59: ...tch settings Refer to Figure 2 1 and follow these steps if you need to change one of these straps Procedure 1 With your thumbs under the edge of the front bezel firmly press upward to lift the bezel f...

Page 60: ...tlet that is protected by a circuit breaker Label the circuit breaker that protects the ac wall outlet and make sure that it is set to ON Allow 1 to 2 feet of clearance around the DSU for access and c...

Page 61: ...to ON EIA level during Test mode When disabled the leads are not connected internally The indicator lead for each interface can be enabled or disabled independently Table 2 2 Model 3610 DSU Jumper Str...

Page 62: ...protects the wall outlet and be sure it is set to ON 3 At the rear of the DSU Figure 2 3 insert the small end of the power cable into the power receptacle If you have a table top ac transformer conne...

Page 63: ...loopback was in progress during the power up procedure These tests take about 20 seconds to complete If the DSU fails the power up test Procedure 1 Confirm the hardware options that are installed if a...

Page 64: ...connections between the tributary and the extended control DSUs an 871A 6 pin turnover adapter is required feature number 4400 F1 594 labeled 002 0025 0031 Procedure 1 Configure the DSU for either CC...

Page 65: ...uration options of the Model 3610 or 3611 DSU from the DCP or of the Model 3610 from an async terminal select the Local branch and then the Configuration Confg branch If not displayed press the key un...

Page 66: ...ed format and or the NMS commands refer to your NMS documentation DDS or LADS Network Connection NOTE Before connecting the DSU to the DDS network ensure that approved primary protectors have been ins...

Page 67: ...Verification Testing section Appendix E provides connectivity diagrams should you need further assistance in connecting the DSU to the network Verification Testing Verification testing should be perfo...

Page 68: ...Models 3610 and 3611 Dial Backup Module and SNA Diagnostic Interface Options Applications Guide Replacing Firmware of an Installed Model 3610 DSU To replace or upgrade the firmware in a Model 3610 DS...

Page 69: ...non modular Model 3611 DSU and the Modular 3611 DSU The non modular Model 3611 DSU has two DTE connectors a 25 pin EIA 232 D V 24 connector and a 34 pin V 35 connector mounted directly onto the rear...

Page 70: ...notified before you connect the DSU Refer to the notice at the front of this manual to ensure compliance with FCC Bell Canada and Canadian DOC rules For DSUs with integrated backup modems coordinate...

Page 71: ...f the card Pins 1 and 2 Disable Put the jumper on the two pins nearest the rear of the card Pins 2 and 3 This is the factory default setting Table 3 2 lists the jumper straps for the Model 3611 DSU no...

Page 72: ...actory Test J203 Left Left A standard EIA 232 cable is being used or the NMS Adapter Cable is being used for the 48 Vdc alarm monitoring Right The NMS Adapter Cable is being used for the diagnostic ch...

Page 73: ...Refer to the appropriate section for the type of 3611 DSU you are installing Installing a Non Modular 3611 DSU To install a non modular 3611 DSU in the COMSPHERE 3000 Series Carrier Procedure 1 Use a...

Page 74: ...its telephone number here as well 5 The rear of each Model 3611 circuit card has an EIA 232 D V 24 ISO 2110 25 pin connector for operation at rates up to and including 19 2 kbps and a ITU T V 35 ISO 2...

Page 75: ...ocedure for the Modular 3611 DSU requires the installation of a rear connector plate onto the rear of the COMSPHERE 3000 Series Carrier After the initial installation the DSU can be installed and remo...

Page 76: ...nector refer to Figure 3 5 and perform the following steps a Connect the 25 pin end of the modular DSU V 35 adapter to the bottom DTE connector of the rear connector plate Tighten the thumbscrews on e...

Page 77: ...DSU see Appendix E of this guide For pin assignments see Appendix F Software Configuration The Model 3611 is configured at the factory as a control to operate at 9 6 kbps Factory set configuration op...

Page 78: ...Series DSU configuration options in a matrix coded format The matrix consists of 11 rows labeled A through K and eight columns labeled 1 through 8 For example position G6 represents the option Link C...

Page 79: ...configuration option to V 35 before the DSU can communicate with the DTE The default for this option is EIA232 Refer to Table 6 10 the General Configuration Options 4 Perform the tests described in th...

Page 80: ...tablish a dialed call to the tributary to test for dial tone and that the DSU can make and receive calls 4 Use the Dial command to switch the data to the PSTN circuit enter Dial Backup mode to ensure...

Page 81: ...ch 4 13 Test Branch 4 14 Abort 4 15 Device Test 4 16 Loopback 4 17 Local Loopback 4 17 DTE Loopback 4 18 Digital Loopback 4 19 Remote Digital Loopback 4 20 Bilateral Loopback 4 21 Digital Test 4 22 En...

Page 82: ...Series Carrier The DCP for both models provides a 2 line 16 character liquid crystal display LCD and keypad through which you access menus to Monitor for health and status Initiate dial backup operat...

Page 83: ...s on the DCP of the Model 3610 DSU and on the faceplate of the Model 3611 DSU continuously provide information on the current operating condition of the DSU All of the status indicators on the Model 3...

Page 84: ...nal lead states at DSU DTE interface circuit designations Control circuit active or Data circuit SPACEing For the DSU with TDM or MCMP the circuit external lead states for any of the TDM or MCMP ports...

Page 85: ...three selections can be displayed at one time Use the or key to move the viewing window left or right and scroll the remaining selections into view All menus wrap around that is scrolling to the right...

Page 86: ...Msgs selection displays only if a message has been received and not cleared Once the message is cleared the Msgs selection no longer appears Messages operation is discussed in the Messages Branch sect...

Page 87: ...us Stat branch provides reports on health and status of the DSU and DBM the DTE s EIA 232 D and V 35 interfaces the identity of the DSU model number serial number etc identifies the terminal s power c...

Page 88: ...displayed press the or key to scroll menu selections into view In most examples additional menu selections are shown beneath the display Status Branch The Status Stat branch reports on the health and...

Page 89: ...fected DSU to light To access the Health and Status reports from the top level menu make the following selections Local F1 or Remot F2 and Address Stat H S Devic Expan or Subn Device Health and Status...

Page 90: ...l mode The downstream DSU s network address and status is displayed on the first line Press the F1 key to display the next highest network address press the F2 key to display the next lowest network a...

Page 91: ...st one transition between Off MARK and ON SPACE has been detected during the monitoring window Circuit Quality Status Circuit Quality CircQ status displays the level and quality of the signal being re...

Page 92: ...yy y indicates the DBM s maximum speed z designates whether the DBM Primary Core option was enabled A P in the z position indicates Primary Core is enabled Only appears when a DBM is installed MUX Ca...

Page 93: ...m Power On F2 F3 If power is detected on the RTS lead the second line displays On If no power is detected on the RTS lead the second line displays Off Backup Branch The Backup Bckup branch controls op...

Page 94: ...ted while the test is in progress For a single port configuration with nondisruptive diagnostics and or rate adaption you can request a Port test on the active core only In addition you can request an...

Page 95: ...ted Secondary channel is restored when the test is aborted 4 Not valid when the configuration option Diag Mode is set to None Abort The Abort selection allows you to abort a test that is running The D...

Page 96: ...Device Test appear momentarily on the DCP s LCD To access the Device Test from the top level menu make the following selections Local F1 or Remot F2 and Address Test DSU Devic For a DSU the Device Te...

Page 97: ...s Local Loopback from the top level menu make the following selections Local F1 Test DSU Lpbk LL While the DSU is in Local Loopback any data transmission by the DTE is returned as received data Figure...

Page 98: ...y To access the DTE Loopback from the top level menu make the following selections Local F1 Test DSU select active core Lpbk DTE Port Select not displayed when operating in single port mode NOTE Only...

Page 99: ...nd RespondRDL Respond to Remote Digital Loopback Selecting Aggr Aggregate loops back the user transmitted data as well as the in band secondary channel transport data if nondisruptive diagnostics are...

Page 100: ...as a tributary DSU can originate a Remote Digital Loopback in a point to point network only For a DSU Remote Digital Loopback is session disruptive except when a dial backup session is active It is us...

Page 101: ...ing DSUs until Remote Digital Loopback is aborted Bilateral Loopback Bilateral Loopback is a combination of DTE and Digital Loopbacks operating simultaneously in the same DSU which is shown in Figure...

Page 102: ...rn is passed to the DSU s comparator to be checked for errors Figure 4 9 At the conclusion of the test the local DSU releases the remote DSU from Digital Loopback The Digital Test is session disruptiv...

Page 103: ...U Address 1 2 3 Enter F2 F3 The address of the tributary DSU being tested is entered if the initiating DSU is a control This screen is not displayed if the DSU is a tributary F1 RunTim 0 01 09 Enter F...

Page 104: ...t was not run on an aggregate data path the Digital Test was run on port nn End to End Test The End to End EE test is used to analyze a control and tributary DSU and the network circuit between them i...

Page 105: ...F3 If the End to End Test is already in progress Start will not be displayed F1 DSU EE Active Time 0 00 11 F2 F3 F1 DSU EE Active Tot Block 100 F2 F3 F1 DSU EE Active Rx Blk err 2 F2 F3 F1 DSU EE Acti...

Page 106: ...e DSU test and via the dial circuit for the DBM test It can monitor the results in one of the following ways Putting the remote DSU into Digital Loopback and checking the returned pattern for errors F...

Page 107: ...ny key except the key returns you to the Bit Error Rate Test submenu where the Displ and Clr selections cause the following to be displayed F1 DSU BERT Active Time 0 01 26 F2 F3 F1 DSU BERT Active Tot...

Page 108: ...select active core Lamp Results If all LEDs are functioning all the indicators on the Model 3610 DCP are flashing steadily In a COMSPHERE 3000 Series Carrier the indicators on the SDCP remain ON The...

Page 109: ...the Configuration branch menu Table 4 9 Configuration Branch Menu Selections Menu Selections Configuration Parameters Requested Opts Configuration options PList1 2 Poll list commands Dir3 Telephone di...

Page 110: ...ded into a working buffer Usr1 Usr2 and Usr3 are storage areas for user defined configuration option sets This feature allows the rapid loading of an entire configuration option set saving the time re...

Page 111: ...st otherwise the control DSU will time out waiting for an upstream diagnostic message from a DSU that is incapable of sending such a message PList is only available in the Local branch and only to a D...

Page 112: ...list The DSU polls all valid addresses The addresses that respond are added to the poll list To acquire the poll list F1 Poll List Chang Add Acq F2 F3 F1 Acquir Poll L 2 Abort F2 F3 Abort allows you t...

Page 113: ...s Load Save F2 F3 F1 Net Address 255 Undo F2 F3 The current stored address displays If the numeric field of the address displays then the configuration has been corrupted and you must restore the netw...

Page 114: ...e or mixed diagnostics Both the control and tributary DSUs must be configured for the same protocol and in a carrier mounted configuration the SDU must be configured for the same protocol ADp DPII or...

Page 115: ...word press CR and then select 2 Save To enter or change the customer identification that appears at the top of each async terminal screen e g to change from a unit identifier to a site identifier sele...

Page 116: ...a DBM is installed and if the DSU is operating in Local mode F1 DSU Enable Enab Disab F2 F3 F1 DSU Disable Command Complete F2 F3 Press any key except the key to clear the Command Complete message Wh...

Page 117: ...he configuration option External Leads Ext Leads is set to ExtLd you can change the state of the two output leads from the DCP or a 6700 or 6800 Series NMS If the DSU s diagnostic protocol is ADp and...

Page 118: ...from the External Leads submenu The following appears F1 OutA OutB Save F2 F3 On this display the F1 key selection toggles the display between and for one lead at a time The field where the cursor is...

Page 119: ...mes per second if a message is waiting You can read messages at the local DSU by selecting Read F1 Messages Read Clear F2 F3 Press the F1 key to select Read If the message is less than 16 characters f...

Page 120: ...COMSPHERE 3600 Series Data Service Units 4 40 July 1999 3610 A2 GB91 90 This page intentionally left blank...

Page 121: ...s not been set on the DCP before the following displays F1 FP Access Lock Unlock Save F2 F3 To select the security level Procedure 1 Press the key to ensure that you are at the top level menu 2 Press...

Page 122: ...ace When the user is ready to return to the Async Terminal mode from the home screen 4 Select Local F1 5 Press the key until Confg appears and select Confg 6 Press the key until Term appears and selec...

Page 123: ...ides start up and network verification information for a DSU optioned with MCMP only If the MCMP option is not installed proceed to the Verification Procedure section The Acquire Poll List command mus...

Page 124: ...uipment Central Site Procedure and one to test equipment only Remote Site Procedure Follow the appropriate procedure provided Central Site Procedure Request a Device Health and Status check Devic from...

Page 125: ...mand Complete appears If there was a facility fault with the remote device or the poll list address was incorrect the message No Response appears If the remote device will not go into Test mode the me...

Page 126: ...tion at the control DSU using the Disc selection Local Bckup Disc F1 DBM Drop Bkup Please wait F2 F3 F1 DBM Drop Bkup Command Complete F2 F3 The Dial LED will flash rapidly to indicate the Dial connec...

Page 127: ...ing screen F1 Device DSU MUX Pass Pass F2 F3 MUX is only displayed if a TDM or MCMP circuit card is installed If the device is not functioning properly Fail appears on the second line instead of Pass...

Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90...

Page 129: ...save changes and provides Configuration Option Tables that describe each configuration option in an option set and its selections Option Sets There are eight configuration option areas or option sets...

Page 130: ...ded configuration options for a tributary DSU are contained in this area FacT The factory loaded configuration options for a central site DSU equipped with a digital bridge are contained in this area...

Page 131: ...ed The first line of each option menu shows the name of the configuration option and the current value The second line of each option menu lists the values available for selection using the function k...

Page 132: ...key for Usr3 or key for Usr2 If Activ is selected any changes made to the configuration options take effect immediately If Usr1 Usr2 or Usr3 is selected the complete set of configuration options incl...

Page 133: ...ration options then an event such as RTS changes results in the subsequent CTS circuit behavior such as CTS changes with RTS Backup Configuration Options The Backup configuration options Table 6 8 det...

Page 134: ...configuration options must be set for each control and tributary DSU involved in the LPDA 2 monitoring Order the COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Dial Backup Module and SN...

Page 135: ...en from the DSU RXC Receive clock source The DSU generates its transmit timing from the receive data signal This choice is provided for LADS configurations It differs from the DDS selection during tes...

Page 136: ...eived clock lead on EIA 232 D Pin 17 or V 35 Pins V and X The DSU uses its own system timing to clock data out of the buffer Transmit Elastic Store is reset upon power up overflow or after the request...

Page 137: ...he DTE Port configuration option is set to V 35 the aggregate data is bridged to the EIA 232 interface Enab Enable this configuration option for aggregate switch backup Disab Disable this configuratio...

Page 138: ...ort is derived to carry diagnostics data between the control and the tributary DSUs Nondisruptive diagnostics are unavailable using the DMC protocol Disr Disruptive Diagnostics The same primary channe...

Page 139: ...hannel Diagnostic Transport Speed entered is 400 The resulting DSU port speed is 9 2 kbps Refer to the following list for valid diagnostic speeds NOTE When the TDM is operating at a line speed greater...

Page 140: ...is a 2600 Series DSU and the tributaries are 2600 3500 3600 Series DSUs or when the control is a 3600 Series DSU and at least one tributary is a 2600 or 3500 Series DSU This selection is not availabl...

Page 141: ...s are allowed 2nd Ch bps 400 Next 100 400 800 1200 1600 Prev In band Secondary Channel Diagnostic Transport Speed in bps Determines the DBM s port speed when NonD nondisruptive diagnostics is selected...

Page 142: ...agnostic General Configuration Options Position Cntrl or Trib Next Cntrl Trib G2Trb Prev Network Position 1 Determines the DSU s position in the network and defines its test and diagnostic capabilitie...

Page 143: ...ion option to greater than or equal to the maximum amount of time it takes for the front end processor FEP to complete its polling cycle on that circuit multiplied by the value entered in Resp Period...

Page 144: ...nd the configuration option Extend Chan is set to Yes set this configuration option to the upstream port number Select Prt1 if the tributary DSU is operating in single port mode This configuration opt...

Page 145: ...e Fast Select feature Disab Disables the Fast Select feature When disabled all devices on the same level of the circuit must be disabled Table 6 5 1 of 6 DBM Configuration Options Rate Kbps 9 6 Next 1...

Page 146: ...Clock Source This source is used when the DSU is connected to a DDS network and the network provides the timing DSU should not be selected if the DSU and DBM operate at different rates CarrLossDisc Ye...

Page 147: ...1 The DSU uses its own system timing to clock data out of the buffer The Transmit Elastic Store buffer is reset upon power up overflow or after the RTS lead makes an Off to ON transition Enab Enable...

Page 148: ...the DBM to answer incoming calls only when the DSU reports a Facility Alarm No security checking is performed This feature is provided for customers that provide data services to other customers that...

Page 149: ...Dial Test When enabled the DBM periodically checks for a signal or dial tone If the test fails the DSU reports a Dial Test Failure alarm in its health and status reports A Dial Test occurs once every...

Page 150: ...incoming calls When Primary Core is set to Yes and Ansr is selected the DBM answers a backup call from the remote DBM when DTR is raised It drops the call when DTR goes low or will not answer an incom...

Page 151: ...e or mixed diagnostics rate adaption or when configuration option M PtSymPrt is enabled this configuration option should be set to DTE FrcOn Model 3610 Factory loaded control FacC DSU keeps the intern...

Page 152: ...value from 1 to 100 second s in increments of 1 When Disab is selected streaming terminal detection is not provided When using async terminal enter 0 zero to disable LSD Lead Std Next Std Delay FrcOn...

Page 153: ...tion options on a per port basis in the MUX submenu Enab DSR is ON continuously during testing allowing a DTE that relies on DSR being ON to send test messages to the DSU Disab DSR is Off during testi...

Page 154: ...18 or Pin L is turned ON Local Loopback ends when the signal is dropped Disab The DTE will not initiate Local Loopback in response to the signal on Pin 18 or Pin L RL by DTE Disab Next Enab Disab Prev...

Page 155: ...a port should not fall back and remain at the same speed then the fallback feature in the DCE connected to that port should not be enabled This feature only works with firmware greater than version 3...

Page 156: ...he control s and tributary s DSU SW Vers configuration option must be set to Normal and the tributary DSU s set to Normal or No If the control DSU s software version is less than 5 15 the following co...

Page 157: ...en a dial backup session is initiated at the local site AnswExtBU should be disabled so that the DSU controls the DSR lead on the aggregate port via the DSU s DCP or the NMS By selecting the Backup co...

Page 158: ...tion is enabled 6 to 10 Selects the asynchronous bits per character When Stop Bits is set to 2 10 will not be displayed Stop Bits 1 Next 1 2 Prev Stop Bits Specifies the number of stop bits in an asyn...

Page 159: ...TS changes LSD Off DDS alarm Test mode ON CTS changes with RTS 21 bit delay CTS Unaffected CTS Off after delay 4 CTS Off RTS Control DTE CTS Control Std or RTS CTS Lead Std or Delay Circ Assur Enab RT...

Page 160: ...Prev Backup on Control Mode Idle 1 This configuration option determines whether the DSU treats a control mode idle CMI condition as a facility alarm to trigger automatic dial backup Configuration opt...

Page 161: ...isabled normal calling cycle Only 10 call attempts are made for the normal calling cycle If a call attempt is in progress and the timer expires the call attempt will not be aborted Chang Calls up a da...

Page 162: ...ture Disab Disables the digital sharing feature Lowest Port 1 Next 1 2 3 4 5 Prev Lowest Port Number Allows selection of the lowest port number to be included in the digital sharing group This configu...

Page 163: ...d The following rules apply All ports in a group must have the same port speed All ports must be adjacent A digital sharing group can have from 2 to 6 ports Enab Enables the digital sharing feature Di...

Page 164: ...an FEP port sharing group consisting of Ports 1 and 2 Enab 3 FEP transmissions and controls pass through Port 1 into the multiplexer and also onto Port 2 Data to be sent to the FEP is demultiplexed fr...

Page 165: ...te one of two contention or digital sharing groups for TDM backup of MCMP The following rules apply All ports in a group must have the same port speed All ports must be adjacent A contention group can...

Page 166: ...other port is active RTS ON The host protocol must enforce the order of transmission to avoid collisions DSD Digital Sharing Device port contention Controls CTS to ensure that only one port is active...

Page 167: ...s displayed only if Sharing Device B is enabled Host No port contention Causes CTS to turn ON for any port that has RTS turned ON even if another port is active RTS ON The host protocol must enforce t...

Page 168: ...ng feature for Ports 3 and 4 P5 6 FEPSh Disab Next Enab Disab Prev Ports 5 and 6 FEP Port Sharing Allows you to create an FEP port sharing group consisting of Ports 5 and 6 This configuration option w...

Page 169: ...DCE port on the digital bridge to the DDS core Select this value for S Multipoint LADS operation S Multipoint dial backup where partial backup is possible 56 to For multipoint dial backup if the DSU...

Page 170: ...or higher for multipoint dial backup where only full backup is possible DDS 19 2 kbps or greater Selects the number of ports This configuration option does not appear when a 2 port TDM Flex or MCMP F...

Page 171: ...ust enforce the order of transmission to avoid collisions The connected DBM V DBM S or DBM D is not required to have V 13 switched carrier emulation In CBrdg mode this is the only available option if...

Page 172: ...n option is enabled Option Verification When 1800 bps is selected the DSU verifies that the synchronous port speed is 2400 bps or greater If only one stop bit is used the asynchronous rate cannot be e...

Page 173: ...carrier operation using the V 13 codes on an individual channel The simulated switched carrier operation is also referred to as pseudo controlled carrier PCC mode It is required for applications where...

Page 174: ...V 13 codes used by the V 13 protocol so they do not pass to the receiving DTE This configuration option is only valid when RxCarrSel is set to Cntrl For an asynchronous port configured for switched ca...

Page 175: ...ts RTS lead constantly turned ON by disabling the DTE If the DTE turns ON RTS longer than the time specified for the AntiStream configuration option the tributary DSU turns ON its alarm indicator and...

Page 176: ...configuration option to No if you do not have an extended network Upstrm Port Prt1 Next Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 Prev Upstream Port If an extended control DSU has its main primary channel connec...

Page 177: ...and W provided by the extended circuit received clock lead on Pin 17 The DSU uses its own system timing to clock data out of the buffer Elastic Store is reset on power up overflow or after the request...

Page 178: ...r disabled A test resets the streaming terminal timer When the test is completed the timer starts again Upon detecting that RTS is no longer turned ON the DSU turns Off its alarm and resets the stream...

Page 179: ...Prt5 Prt6 Prev Upstream Port If an extended control DSU has its main primary channel connected to a tributary DSU and the tributary s Extend Channel configuration option is set to Yes set this option...

Page 180: ...aggregate rate an underspeed port selection is required Underspeed Disab Next Disab Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 Prev Underspeed Port Selects which port is run slightly underspeed to allow for in ban...

Page 181: ...transport if used If more than one port is active including the in band secondary channel transport and the sum of the speeds not included in the in band secondary channel transport equals the primary...

Page 182: ...eeds does not exceed the primary aggregate speed set in the DSU s Rate Kbps configuration option If the sum of the port speeds equals the primary aggregate rate an underspeed port selection is require...

Page 183: ...the group At one or more tributary sites a channel can be assigned to as many ports as wanted to establish the virtual multiport circuit for that channel when Port Control is set to Host A to F Assign...

Page 184: ...set to RTS Disab The 3600 Series DSU does not respond to LPDA 2 commands LPDA Address 001 Next Chang Prev LPDA Address Allows the LPDA 2 address used by NetView to be set Choices are 1 through 255 in...

Page 185: ...ommand Code 1 582210 Next Chang Prev Code 1 Determines the DSU type and model that the 3600 Series DSU reports to NetView for the DSU CSU and Line Status test and Transmit Receive Test commands The de...

Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90...

Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A...

Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90...

Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999...

Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90...

Page 191: ...MP operating in Bridge mode A Configuration Worksheet summarizes the DSU s option sets configuration options and configuration option values The Configuration Option Tables in Chapter 6 provide an exp...

Page 192: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB91 90 This page intentionally left blank...

Page 193: ...CC Buffer Enab Disab Elast Stor Enab Disab RTS CTS Del Chang 0 1040 ms 8 ms increments DTR Alarm Enab Disab AntiStream Chang Disab 1 100 sec async terminal 0 100 DSR FrcOn Enab Disab DSR on Tst Enab D...

Page 194: ...18 0 16 8 14 4 12 0 9 6 9 2 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Prt6 56 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 9 2 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Underspeed Disab Prt1 Prt2 Prt3 Prt4 Prt5 Prt6...

Page 195: ...8 9 10 Hardware Straps Value DDD Interface Permissive Programmable Frame Ground Signal Ground Connected Disconnected Test Mode Indication Enabled Disabled ChgMd Options Value Mode DPII ADp DMC Not ava...

Page 196: ...Mark PCC Buffer Enab Disab Elast Stor Enab Disab RTS CTS Del Chang 0 1040 ms 8 ms increments DTR Alarm Enab Disab AntiStream Chang Disab 1 100 sec async terminal 0 100 DSR FrcOn Enab Disab DSR on Tst...

Page 197: ...ue Prt1 56 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Prt2 56 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Prt3 56 48 38 4 32 28 8...

Page 198: ...Options Value Auto Bckup Enab Disab Backup Dir Chang 1 10 BckupOnCMI Enab Disab AutoRestor Enab Disab NtwkTimOut Chang min and sec RestorTimOut Chang min TriesTimeOut Chang min MultiCall Enab Disab H...

Page 199: ...rl Mark PCC Buffer Enab Disab Elast Stor Enab Disab RTS CTS Del Chang 0 1040 ms 8 ms increments DTR Alarm Enab Disab AntiStream Chang Disab 1 100 sec async terminal 0 100 DSR FrcOn Enab Disab DSR on T...

Page 200: ...ggrSwitch Enab Disab AgSw Timing Int Aggr Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 V 54 Lpbk Enab Disab LPDA 2 Options Value LPDA 2 Enab Disab LPDA Address Chang 1 256 SNA Backup Enab Disab Code 1 Chang Code 2 C...

Page 201: ...r Type 2500 2600 3600s 3600e Br56 Diagnostic DBM Options Value Diag Type NonD Disr Mixed None 2nd Ch bps 100 400 800 1200 1600 RemoteDiag V 54 Enhan 2500 Diagnostic General Options Value Position Cntr...

Page 202: ...or DBM D only DBM D only General Options Value DTE Port EIA232 V 35 RTS Cntrl FrcOn DTE CTS Cntrl Std RTS AnitStream Chang Disab 1 100 sec async terminal 1 100 LSD Lead Std Delay FrcOn CTS Lead Std De...

Page 203: ...lth and status and Subnetwork Subn health and status messages In addition dial backup progress and error messages as well as time division multiplexer TDM multichannel multipoint MCMP and digital brid...

Page 204: ...below apply If problem cannot be corrected call your service representative Conflict w Envir Command conflicts with test in progress configuration inappropriate for this command etc 1 Check for a test...

Page 205: ...d Status Messages Message Condition CMI Fac Alarm Backup on CMI configuration option is enabled and control mode idle CMI is being received Config Corrupt Configuration is corrupt Reset all configurat...

Page 206: ...de init is one of the following initiators DTE Data Terminal Equipment FP Front Panel the DCP LPDA NetView initiated test NMS Network Management System Ntwk Network Switched 56 DBM only Remt Remote DS...

Page 207: ...s configuration option External Alarm B The DSU detects a positive voltage on Pin 19 This alarm condition is defined by the Ext Leads configuration option Invalid Address A DSU was powered up with an...

Page 208: ...treaming terminal DTE at port nn 01 06 All has its RTS lead turned ON longer than the predefined time PnnTst test init The DSU is running a test on port nn 01 06 initiated from init test is one of the...

Page 209: ...dialed connection is made but the data is still routed over the DDS circuit The first line shows the dial backup connection time Active A dialed connection is made and data has been routed over that...

Page 210: ...ttempts include Abort Call User aborted call BadPermiss A dial backup connection currently exists Bad Phone Unassigned number or illegal characters Busy Line or network busy DBM Disab DBM disabled no...

Page 211: ...DTE alarm Data Terminal Ready lead is Off ExtLd External lead alarm a or b Facil DDS facility alarm Indicates a network facility alarm MAJOR Indicates a major alarm from a DATAPHONE II device MUX MUX...

Page 212: ...l backup Clock source is determined by the DSU TxClkSource configuration option AggSw w o DDS Aggregate switch in full backup Clock source is determined by the AgSw Timing configuration option Brdg wi...

Page 213: ...l DBM Callback Callback sequence initiated DBM Connected Connected DBM Disabled No calls can be initiated or answered DBM FoundAnswTon A 4 wire Switched 56 DBM is answering an incoming call DBM Ringin...

Page 214: ...made to place a call from an empty directory Check Backup Directory entries and numbers DBM DTR Discon Yes DTR has gone low or the call did not connect Raise DTR at the DTE or disable the DTRCallCon...

Page 215: ...DBM s configuration options to ensure that DBM is enabled 3 If you cannot correct the problem contact your service representative DBM ProtoErrnn No Protocol error nn is the error number by the 2 wire...

Page 216: ...d TDM mode An attempt was made to run an asynchronous port at underspeed A port configured for asynchronous operation cannot be configured to run underspeed Choose a synchronous port and configure it...

Page 217: ...ort speeds is less than or equal to 48 kbps DBM CBRDG Incmpt Bridge mode An attempt is made to configure a DSU equipped with a DBM as a central site bridge A DSU is not allowed to be configured as a c...

Page 218: ...guration where Bridge Rate is set to any value but DSU elastic store must be turned Off at each of the active bridge supports Set configuration option ElasStor Elastic Store to Disab for each of the a...

Page 219: ...path in the MUX configuration submenu Bridge mode 1 first port on TDM MCMP was previously selected as the first port in a digital sharing group when DSU was operating in TDM or MCMP mode and DSU is no...

Page 220: ...be the source of external timing when operating in TDM or Bridge mode valid external timing selections are Prt1 through Prt6 for TDM mode and Prt1 for Bridge mode Set configuration option TxClkSource...

Page 221: ...r a central site bridge configuration sourcing external timing on Prt1 set the Bridge Rate configuration option to DSU 1 OnePrt no undspd TDM mode Only one port is active and an attempt is made to con...

Page 222: ...st be set to DTE When a port s TxCarrSel is set to Const its RTS Cntrl must be set to FrcOn Set configuration options Transmitter Carrier Select TxCarrSel and RTS Control RTS Cntrl to compatible setti...

Page 223: ...Number of Ports in Group 5 Select new specifications for the digital sharing group via the Setup path in the MUX configuration submenu Undersp Required TDM mode The sum of the port speeds equals the...

Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90...

Page 225: ...async terminal as if using the DCP but without the limitation of the 2 line 16 character LCD An entire menu or submenu test result or range of configuration options appears on a single screen Refer to...

Page 226: ...e the password entered select Undo F1 Pswrd _ _ _ _ _ _ _ _ Undo F2 F3 Enabling the Async Terminal To enable the async terminal Procedure 1 Ensure that the terminal is connected physically to the DSU...

Page 227: ...a session refreshes the async terminal s screen NOTE When no entries are made for 5 minutes the async terminal session is terminated and a blank screen appears When the carriage return CR key is pres...

Page 228: ...To terminate a session enter Ctrl x Refer to the Terminating a Session section of this chapter for additional information Selection Screens Selection screens display the selections available through...

Page 229: ...ion screen appears and is comparable to selecting the Confg branch from the DCP Figure D 4 Customer ID SITER818 Model COMSPHERE 3610 Local Mode 1 Stat T Ctrl T Top Menu 2 Bckup U Ctrl U Up Menu 3 Test...

Page 230: ...al Leads Input screen appears Figure D 7 The OutA or OutB field will be highlighted To change the value of the bolded field PRESS 1 Toggle The highlighted field will change from high to low or vice ve...

Page 231: ...u 2 Chang U Ctrl U Up Menu PRESS Desired Selection Key Ctrl x Disconnect Figure D 6 External Leads Menu Selection Screen Customer ID SITER818 Model COMSPHERE 3610 OutA OutB _ 1 Toggle T Ctrl T Top Men...

Page 232: ...D 9 set up or change the Customer ID as follows PRESS 1 Chang 4 The Customer ID input screen appears Figure D 10 The Customer ID can be up to 8 characters Valid characters include Alpha characters A t...

Page 233: ...rl T Top Menu 2 Disab U Ctrl U Up Menu 3 Pswrd 4 CID PRESS Desired Selection Key Ctrl x Disconnect Figure D 8 Async Terminal Menu Screen Customer ID SITER818 Model COMSPHERE 3610 Term CID 1 Chang T Ct...

Page 234: ...SPHERE 3610 CID Ctrl T Top Menu Ctrl U Up Menu ENTER Desired Input CR to complete Ctrl x Disconnect Figure D 10 Customer ID Input Screen Customer ID SITER818 Model COMSPHERE 3610 Term CID Command Comp...

Page 235: ...assword input screen appears Figure D 13 The password can be up to 8 characters Valid password characters include Alpha characters a to z upper or lowercase Numeric 0 to 9 Characters pound sign dash p...

Page 236: ...sab To access antistreaming without a MUX select Confg Opts Activ and Gen If MUX is configured select Confg Opts Activ MUX and Prtn To disable or set the amount of time for antistreaming Procedure 1 A...

Page 237: ...Next T Ctrl T Top Menu 2 Chang U Ctrl U Up Menu 3 Prev PRESS Desired Selection Key Ctrl x Disconnect Figure D 14 AntiStream Menu Screen Customer ID SFTCR818 Model COMSPHERE 3610 AntiStream 88s Ctrl T...

Page 238: ...he DSU Digital Test Run Time input screen appears Figure D 19 5 Enter the run time for the Digital Test and press the carriage return CR The following message appears on the screen Please wait NOTE Th...

Page 239: ...rt T Ctrl T Top Menu U Ctrl U Up Menu PRESS Desired Selection Key Ctrl x Disconnect Figure D 17 DSU Digital Test Selection Screen Customer ID SITER170 Model COMSPHERE 3610 Port Number 1 Aggr T Ctrl T...

Page 240: ...Tim 0 00 09 Ctrl T Top Menu Ctrl U Up Menu ENTER Desired Input CR to complete Ctrl x Disconnect Figure D 19 DSU Digital Test Run Time Input Screen Customer ID SITER170 Model COMSPHERE 3610 DSU Digital...

Page 241: ...pears Figure D 21 PRESS 1 H S 3 The Health and Status Menu selection screen appears Figure D 22 PRESS 1 Devic The Device Health and Status Display screen appears Figure D 23 The async terminal refresh...

Page 242: ...op Menu 2 Expan U Ctrl U Up Menu 3 Subn PRESS Desired Selection Key Ctrl x Disconnect Figure D 22 Health and Status Menu Selection Screen Customer ID SITER170 Model COMSPHERE 3610 H S 25 12 45 9 6 DDS...

Page 243: ...ay screen appears Figure D 24 For Identity field descriptions refer to Table 4 4 Identity Descriptions and the Identity section in Chapter 4 Customer ID SITER170 Model COMSPHERE 3610 Identity Model 36...

Page 244: ...x control key plus x The async terminal session is deactivated and returns to the Password Access Menu screen the password must be reentered to reactivate an async terminal session Control can be retu...

Page 245: ...S to a Model 3611 DSU from a Model 3611 DSU to another 3600 Series DSU etc Both the feature and part numbers are provided on these diagrams for easier ordering and verification Instructions To use the...

Page 246: ...COMSPHERE 3600 Series Data Service Units E 2 July 1999 3610 A2 GB91 90 Figure E 1 Control Channel...

Page 247: ...Network Management Connectivity E 3 3610 A2 GB91 90 July 1999 Figure E 2 Extended Control Channel...

Page 248: ...224 0311 10 4400 F1 511 835 1224 1011 25 4400 F1 512 835 1224 2511 871A MODEL 3610 DSU DP II DATAPHONE II UNIT M6BJ M6BJ DC OUT DC IN SDU MODEL 3611 DSU 3600 SERIES DSU NMS ADAPTER CABLE 3000 F2 510 0...

Page 249: ...r pin assignments Figure F 3 shows the Modular DSU rear connector plate while Table F 6 provides the EIA 232 D V 24 connector s pin assignments Figure F 4 shows the Modular DSU V 35 adapter plug that...

Page 250: ...s Pin Assignments Pin Circuit Function 1 R1 Transmit data to local loop 2 T1 Transmit data to local loop 7 T Received data from local loop 8 R Received data from local loop Table F 2 Model 3610 6 Pin...

Page 251: ...4 Pin Modular Plug 496 13775 03 8 1 Pin Numbers 8 1 C C I N D C O U T C C O U T D C I N CC IN DC OUT Hubbing Device CC OUT DC IN Figure F 2 3600 Hubbing Device 3600 F3 300 Table F 3 3600 Hubbing Devic...

Page 252: ...DCORTS CCICTS OUT CTS RTS 4 DCOSD CCIRD OUT RD SD 5 Signal Ground GND GND 6 DCORD CCISD IN SD RD 7 N C N C N C 8 V Pass Through N C N C Table F 5 3600 Hubbing Device CC OUT DC IN Jack Connector Pin As...

Page 253: ...Pin Assignments F 5 3610 A2 GB91 90 July 1999 Figure F 3 Modular 3611 DSU 25 Pin EIA 232 25 Pin V 35 Rear Connector Plate 3000 F1 021...

Page 254: ...ol Lead II 14 SBA 118 Secondary Transmit Data 15 DB 114 Transmitter Signal Element Timing DCE Source 16 SBB 119 Secondary Received Data 17 DD 115 Receiver Signal Element Timing DCE Source 18 LL 141 Lo...

Page 255: ...Pin Assignments F 7 3610 A2 GB91 90 July 1999 99 16294 Figure F 4 Modular DSU V 35 Adapter Plug Figure F 5 Modular DSU V 35 Adapter Cable Feature Number 3000 F1 510...

Page 256: ...eady DSR 8 F Received Line Signal Detect LSD 20 H Data Terminal Ready DTR 21 J Ring Indicator RI 1 18 L Local Loopback LL 19 N Remote Digital Loopback RL 24 11 P S Transmit Data TXD 23 22 R T Received...

Page 257: ...e N C 11 4 Signal Ground Signal Ground 14 3 Unused Output from DSU Secondary Receive Data to DSU 16 5 Unused Output from DSU Secondary Transmit Data from DSU 19 2 Fan Status Alarm Input to DSU Data Si...

Page 258: ...COMSPHERE 3600 Series Data Service Units F 10 July 1999 3610 A2 GB91 90 Figure F 7 DSU CC to DB25 Async Terminal Cable 3600 F3 504...

Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F...

Page 260: ...X U W A B C F H E T R S P L Z W U X V A B F C E H P1 PIN P2 PIN 99 16328 C A D B KK MM LL NN P1 C A D B KK MM LL NN P2 15 FT 0 5 FT TXD A TXD B RXD A RXD B TX CLK A TX CLK B RX CLK A RX CLK B EXT CLK...

Page 261: ...inal Power Dial Tone Test Diagnostic Tests Device Test Local Loopback Digital Loopback Remote Digital Loopback Terminal Loopback Digital Test End to End Test Lamp Test Bit Error Rate Test These status...

Page 262: ...er to the appropriate error messages listed in Appendix C to correct the problem DBM Troubleshooting Digital circuits are generally highly reliable and DBMs may be idle for long periods To ensure that...

Page 263: ...Troubleshooting G 3 3610 A2 GB91 90 July 1999 Figure G 2 No Signal NS Condition Troubleshooting...

Page 264: ...COMSPHERE 3600 Series Data Service Units G 4 July 1999 3610 A2 GB91 90 Figure G 3 Streaming Terminal STR Condition Troubleshooting...

Page 265: ...Troubleshooting G 5 3610 A2 GB91 90 July 1999 Figure G 4 Out of Frame OOF Condition Troubleshooting...

Page 266: ...carrier mounted only and or the Health and Status report for the DSU indicates an alarm in the TDM or MCMP perform the following steps 1 Perform a Device Test on the DSU If the test fails reinstall t...

Page 267: ...mode Release 3 0 or greater is required to fully support a 3600 Series DSU with firmware version 4 25 or greater and is also required to support the new configuration options and option choices as we...

Page 268: ...NMS control channel CC or diagnostic channel DC and are nondisruptive to the primary data channel Since a tributary is remote commands addressed to it can be disruptive unless the associated DBMs are...

Page 269: ...ommands depends on the position of the addressed device in the circuit and the setting of the Diagnostic Type configuration option Commands addressed to a control DSU use the NMS control channel CC or...

Page 270: ...trol channel CC or diagnostic channel DC and are nondisruptive to the primary data channel Since a tributary is remote commands addressed to it can be disruptive unless the associated DBMs are in Stan...

Page 271: ...a control DSU use the NMS control channel CC or diagnostic channel DC and are nondisruptive to the primary data channel Since a tributary is remote commands addressed to it can be disruptive unless th...

Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90...

Page 273: ...e each position represents one value These values are mutually exclusive that is only one matrix position can be turned on Tables I 11 and I 12 identify mutually exclusive option values For options wi...

Page 274: ...DS RXC DBM Clock Source Int DTE DDS RXC Table I 4 C Options Device Matrix Options Device C1 C2 C3 C4 C5 C6 C7 C8 DSU RTS Control FrcOn DTE CTS Control Std RTS Message Clamping Enab Disab Respond to Re...

Page 275: ...ab Auto answer Enab Disab Call Setup Security Remote Diagnos tics Enhan V 35 None PsWd Calbk Table I 6 E Options Device Matrix Options Device E1 E2 E3 E4 E5 E6 E7 E8 DSU 19 2 power level dBm Test Patt...

Page 276: ...Pt 2500 2600 3600s 3600e Table I 9 H Options Device Matrix Options Device H1 H2 H3 H4 H5 H6 H7 H8 DSU LSD Lead Std Delay FrcOn DBM min sec DDD Time Out minutes or seconds per H1 1 1 5 2 10 3 15 4 20 5...

Page 277: ...P P P P P E PX PX PX PX N N N N F PX PX PX PX PX PX PX PX G PX PX PX PX P P P P H PX PX PX PX N N N N I PX PX PX PX N N N N J N N N N N N N N K N N N N N N N N Table I 12 Valid DBM Backup Options 1 2...

Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90...

Page 279: ...tic Type Tributary Type 2500 2600 3600s or 3600e RespondRDL Respond to RDL Request Enabled or Disabled RTS Cntrl1 2500 Request to Send Control Enabled only Continuous RS 2600 Request to Send Control E...

Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90...

Page 281: ...id command Returns either an A ACK or N NACK Device Self Test Initiates the Device Test on a DSU or DBM Returns a Pass or Fail to NMS Diagnostic Self Test Retrieves diagnostic information from a DSU o...

Page 282: ...t all test conditions and return to normal operations It does not enable disable a DSU or DBM that was disabled by the DSU Disable command If the addressed DSU is not in a test mode no action is taken...

Page 283: ...nd 6 port TDM Flex1 With 6 port MCMP Flex1 With V 32bis 14 4 kbps DBM and 6 port MCMP Flex1 With 4 Wire Switched 56 DBM and 6 port MCMP Flex1 With 2 Wire Switched 56 DBM and 6 port MCMP Flex1 3610 A3...

Page 284: ...us 3600 G3 201 3611 B3 003 plus 3600 G3 056 3611 B3 003 plus 3600 G3 256 3611 B3 004 3611 B3 004 plus 3600 G3 201 3611 B3 004 plus 3600 G3 056 3611 B3 004 plus 3600 G3 256 3611 B3 005 3611 B3 008 3611...

Page 285: ...only V 35 EIA 232 3600 G3 603 107155202 DSU CC to DB25 Cable 10i for an Async Terminal 3600 F3 504 107331340 ACCULINKr 3100 Series CSU Wall Mount Adapter for Model 3610 DSU 3100 F1 400 406941674 Mode...

Page 286: ...idge 60 pin Plug to five EIA 232 Plug Interface Connectors for multipoint dial backup 3600 F2 500 3600 F2 501 106314651 106315294 Straight In Plug Socket Mass Termination 50 pin Cable B25A 10i 3000 F1...

Page 287: ...For Model 3610 3611 TDM For Model 3610 3611 MCMP 3600 W3 700 3600 W3 701 3600 W3 702 3600 W3 703 106772429 106772346 106772494 106772551 COMSPHERE 3000 Series Carrier Installation Manual 3000 M3 001 C...

Page 288: ...1 8xxx 870 1837 8xxx 870 1600 8xxx 870 1678 8xxx 870 1870 8xxx 870 1836 8xxx 175 0022 0031 654 0099 0131 Model 3611 DSU non modular CCA DSU R1 R2 CCA DSU R3 R3 1 R3 2 R3 3 CCA DSU R3 R3 1 R3 2 R3 3 CC...

Page 289: ...Switched 56 kbps 102 0136 0031 102 0144 0031 870 1571 8xxx 870 1672 8xxx 870 1671 8xxx 870 1758 8xxx 870 1759 8xxx 035 0211 0031 598 0086 0031 589 0078 0031 870 1707 8xxx 870 1719 8xxx 870 1778 8xxx...

Page 290: ...n to eight 6 pin Modular Network Interface Adapter 1 5i Model 3611 in Canada 50 pin to eight 8 pin Modular Network Interface Adapter 1 5i Model 3611 in U S 035 0258 0231 035 0256 0231 Model 3611 Dial...

Page 291: ...Multipoint and Digital Bridge Options Applications Guide 3610 A2 GB41 COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Secondary Channel Applications Supplement 3610 A2 GB42 COMSPHERE 360...

Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90...

Page 293: ...displays emulate the DCP without being limited to the 2 line LCD display asynchronous transmission A data transmission that is synchronized by a transmission start bit at the beginning of a character...

Page 294: ...hat controls communications processing for multiple terminals CMI Control Mode Idle A control signal sent over the DDS line to indicate that no data is being sent collision A collision occurs when two...

Page 295: ...d 56 DBMs or DBM Ds for backup through the 2 wire Switched 56 digital service The 4 wire Switched 56 DBMs and DBM Ss are only available for use in the U S DBM D A carrier mounted dial backup unit that...

Page 296: ...cess telephone lines without operator assistance DMC Diagnostic MicroComputer The network management protocol used by Paradyne ANALYSIS 6510 NMS DOC Canadian Department of Communication drop A tributa...

Page 297: ...ndwich of two sealed glass plates containing liquid crystal material When voltage is applied the amount of light able to pass through the glass plates is altered so that messages may be written on the...

Page 298: ...sruptive diagnostics Diagnostics that are transmitted over the in band secondary channel or routed through a DBM in Standby mode so that bandwidth assigned to the data is not affected non disruptive s...

Page 299: ...ptive diagnostics Diagnostic messages with a duration of 5 seconds or less that are sent over the primary data channel These messages may interrupt customer data causing errors requiring retransmissio...

Page 300: ...UL Underwriters Laboratories Inc USOC Universal Service Ordering Codes Virtual Telecommunications Access Method VTAM An IBM program product that controls communication and the flow of data in an SNA n...

Page 301: ...sync terminal D 12 input screen D 13 general configuration options 6 24 port configuration options 6 47 6 50 application DBM D 1 36 DBM S 1 35 digital bridge 1 39 hubbing device 1 36 MCMP 1 38 TDM 1 3...

Page 302: ...assignments F 9 F 22 async terminal F 10 crossover EIA 232 F 11 V 35 F 12 V 35 adapter F 7 installation 3 8 Call Setup DBM configuration options 6 20 carrier rear view COMPSHERE 3000 3 6 CarrLossDisc...

Page 303: ...dresses 1 18 1 24 CTS Cntrl general configuration options 6 23 CTS interface lead configuration options 6 31 CTS Lead general configuration options 6 24 customer ID 4 35 D data rates 1 32 DBM D 1 36 D...

Page 304: ...26 interface 1 29 port 1 37 lead status codes 4 11 loopback 4 18 port interface 1 38 1 39 status 4 10 DTE Port general configuration options 6 23 port configuration options 6 48 DTR Alarm general con...

Page 305: ...LCD display 4 5 power up 2 7 3 7 LEDs selection 4 37 line speeds MCMP 1 38 link delay diagnostic configuration options 6 15 LinkConfg diagnostic configuration options 6 14 link level network address...

Page 306: ...onfiguration options 6 33 multichannel multipoint 1 13 multipoint backup progress messages C 10 circuit 1 13 configuration 1 7 1 24 aggregate switched backup 1 25 multichannel 1 13 network async compa...

Page 307: ...options 6 36 P3 4 FEPSh MCMP configuration options 6 40 TDM configuration options 6 36 P5 6 FEPSh MCMP configuration options 6 40 TDM configuration options 6 36 packet delay diagnostic configuration...

Page 308: ...ack 4 20 Remote Diag DBM configuration options 6 14 remote site procedure 5 5 report external lead changes 4 38 identity 4 11 field descriptions 4 12 terminal power 4 13 Resp Period diagnostic configu...

Page 309: ...e C 1 terminal async 4 34 D 1 power report 4 13 test bit error rate 4 26 branch 4 7 4 14 menu 4 15 device 4 16 diagnostic troubleshooting G 1 G 6 test continued digital 4 22 end to end 4 24 lamp 4 28...

Page 310: ...COMSPHERE 3600 Series Data Service Units Index 10 July 1999 3610 A2 GB91 90 W warranty support 1 40 weight DSU 1 31 hubbing device 1 36...

Reviews: