Configuration Options
6-25
3610-A2-GB91-90
July 1999
Table 6-6
(3 of 8)
General Configuration Options
DSR FrcOn: Enab
Next Enab Disab Prev
Data Set Ready Forced On. Provides the ability to override any other options controlling the Data Set Ready
lead.
In TDM, MCMP, CBrdg, or EBrdg mode, the DSR FrcOn and DSR on Tst configuration options are not
displayed; rather, you select these configuration options on a per-port basis in the MUX submenu.
Enab
—
DSR remains ON as long as the device is working regardless of tests and network alarms.
Disab
—
DSR functions as an active lead reflecting various test and alarm conditions and other options.
SystemStat: Enab
Next Enab Disab Prev
System Status. Controls the behavior of the DSR lead in response to a No Signal, Out-of-Service, or
Out-of-Frame alarm from the network.
Enab
—
Network alarm turns Off DSR.
Disab
2
—
Network alarm does not affect DSR.
DSR on Tst: Enab
Next Enab Disab Prev
Data Set Ready On in Test. Controls the behavior of the DSR lead during testing.
In TDM, MCMP, CBrdg, or EBrdg mode, the DSR FrcOn and DSR on Tst configuration options are not
displayed; rather, you select these configuration options on a per-port basis in the MUX submenu.
Enab
—
DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send
test messages to the DSU.
Disab
—
DSR is Off during testing.
Circ Assur:Disab
Next Enab Disab Prev
Circuit Assurance. Controls behavior of the CTS lead in response to a data signal from the network. If CTS
Cntrl is set to RTS and RTS Cntrl is set to FrcOn, this configuration option is ignored. Used for single-port
applications only. When enabled, Diag Type should be set to NonD and rate adaption should not be in effect.
A DDS Facility Alarm condition turns Off the CTS lead, regardless of the Circuit Assurance setting.
Enab
—
The DSU will turn Off the CTS lead if the DSU receives control mode idle (CMI) from the
network.
Disab
—
The DSU is not affected by the receipt of CMI.
Tst Pattern: Std
Next AT&T Std Prev
Test Pattern. Selects the test pattern generator and comparator used by the DSU in disruptive testing. This
configuration option only applies to aggregate tests.
AT&T —
Must be selected by a 3600 Series DSU when exchanging test patterns with 2500, 2600, and
3500 Series DSUs.
Std
—
The CCITT standard 511-bit pattern; used with
external test equipment.
2
For a DBM-V, DBM-S, DBM-D, aggregate switching, or when the DSU is in Bridge mode. The SystemStat
configuration option should be set to Disab.
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90...