Operations Manual: HPAC-100/125/150/200/250-RM SSPA
3-31
3 Operation of Stand-Alone Unit
Unit Diagnostics
Response to a Report Unit Diagnostics command. The Data field contains a detailed
list of the voltages and currents for the specified SSPA unit.
Type:
RESPONSE
Pkt Length:
24
Destination:
M&C Address
Source:
SSPA System Address
Command:
0x93
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
RFU1 Voltage
(2 bytes, binary coded decimal)
RFU1 Current
(2 bytes, binary coded decimal)
RFU2 Voltage
(2 bytes, binary coded decimal)
RFU2 Current
(2 bytes, binary coded decimal)
RFU3 Voltage
(2 bytes, binary coded decimal)
RFU3 Current
(2 bytes, binary coded decimal)
+28V Supply Voltage
(2 bytes, binary coded decimal)
Ambient Temperature
(1 byte, 2’s complement)
RFU1 Temperature
(1 byte, 2’s complement)
RFU2 Temperature
(1 byte, 2’s complement)
RFU3 Temperature
(1 byte, 2’s complement)
Length:
26 bytes