Operations Manual: HPAC-100/125/150/200/250-RM SSPA
3-23
3 Operation of Stand-Alone Unit
Set Reflected RF Power Threshold (Reflected power monitor option only)
Sets the threshold above which the reflected RF power is considered to be too high.
This command is only recognized in setup mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x2A
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Power Threshold:
(1 byte, integer)
[ 16 . . 56]
dBm
Length:
9 bytes
Enable Reflected RF Power Fault (Reflected power monitor option only)
Sets whether the reflected RF output power condition is considered a fault and thus
contributes to a summary fault condition. This command is only recognized in setup
mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x2B
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Fault Monitor State:
(1 byte, integer)
0 = DISABLE (OFF) High reflected power fault is deselected.
1 = ENABLE
High reflected power fault is selected.
Length:
9 bytes
Enable Auxiliary Fault 1 Input
Enable or disable fault monitoring of Aux 1 input. The signal is active high (or open
contacts) meaning a high level or open form C contacts will trigger the fault. In
redundant configurations, when enabled this fault will cause external switching to
occur.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x3E
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Fault Monitor State:
(1 byte, integer)
0 = DISABLE (OFF)
Auxilliary fault disabled.
1 = ENABLE (ON)
Auxiliary fault enabled.
Length:
9 bytes