Operations Manual: HPAC-100/125/150/200/250-RM SSPA
3-21
3 Operation of Stand-Alone Unit
Set High Temperature Threshold
Sets the threshold beyond which the unit is considered to be in a state of elevated
temperature. This threshold is used to determine when the unit has recoverd from an
over temperature shutdown condition. This command is only recognized in setup
mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x24
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Temperature:
(1 byte, integer)
[ 40..80 ]
°
C
Length:
9 bytes
Enable High Temperature Fault
Selects whether a detected high temperature condition is considered a fault and thus
contributes to a summary fault condition. This command is only recognized in setup
mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x25
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Fault Monitor State:
(1 byte, integer)
0 = DISABLE (OFF)
High temperature fault is deselected.
1 = ENABLE
High temperature fault is selected.
Length:
9 bytes
Set Low RF Power Threshold
Sets the threshold below which the unit is considered to be transmitting low RF output
power. Also, this threshold is used to determine whether the front panel RF Out LED
is illuminated. This command is only recognized in setup mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x26
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Power Threshold:
(1 byte, integer)
[ 16 . . 56]
dBm
Length:
9 bytes