Operations Manual: HPAC-100/125/150/200/250-RM SSPA
5-3
5 Performance Tests
Parallel Port Monitors and Controls
All parallel port monitors and controls are verified. Due to resistor and the digital to
analog converter tolerances, the value of the differential power monitor at the
amplifier’s rated 1dB gain compression point differs slightly between units. This
value is measured and recorded on the test data sheet.
Serial Port Monitors and Controls
The HPAC-100/125/150/200/250-RM is operated in Remote mode and a sampling of
the serial commands and queries is tested to ensure that the proper responses are
received. These tests are performed using RS-232 and RS-485 protocols.
Summary of Contents for HPAC-100-RM