3-22
Operations Manual: HPAC-100/125/150/200/250-RM SSPA
3 Operation of Stand-Alone Unit
Enable Low RF Power Fault
Sets whether a detected low RF output power condition is considered a fault and thus
contributes to a summary fault condition. This command is only recognized in setup
mode.
Type:
COMMAND
Pkt Length;
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x27
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Fault Monitor State:
(1 byte, integer)
0 = DISABLE (OFF)
Low RF power fault is deselected.
1 = ENABLE
Low RF power fault is selected.
Length:
9 bytes
Set High RF Power Threshold
Sets the threshold above which the unit is considered to be transmitting excessive RF
output power. This command is only recognized in setup mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x28
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Power Threshold:
(1 byte, integer)
[ 16 . . 56]
dBm
Length:
9 bytes
Enable High RF Power Fault
Sets whether a detected high RF output power condition is considered a fault and
thus contributes to a summary fault condition. This command is only recognized in
setup mode.
Type:
COMMAND
Pkt Length:
7
Destination:
SSPA System Address
Source:
M&C Address
Command:
0x29
Data:
Unit ID:
(1 byte, integer)
[ 1 | 2 | 3 ]
Fault Monitor State:
(1 byte, integer)
0 = DISABLE (OFF)
High RF power fault is deselected.
1 = ENABLE
High RF power fault is selected.
Length:
9 bytes
Summary of Contents for HPAC-100-RM