B-6
Operations Manual: HPAC-100/125/150/200/250-RM SSPA
Appendix B
Manual mode, this control provides the means for switching the system configuration.
Mute Status
The front panel mute LED on each unit indicates the mute status of the individual ampli-
fier. Line three of the OPS menu has two provisions for muting. System mute/unmute
controls both amplifiers simultaneously. Unit mute/unmute controls the individual unit the
command is issued to via front panel or remote.
Status Menu
Figure B-3 shows an example Status Menu screen for a redundant system. Line 1
shows the output power of the amplifier and its temperature. Line two shows the
attenuation setting of the amplifier and the mute status of the system.
Figure B-3: Status Menu for a redundant system.
Line 3 is divided into four fields. The first field indicates the control location: LOC for
local or REM for remote. The second field indicates the switching mode: MAN for
manual or AUTO for auto. The third field indicates the amplifier status: Stdby for
standby or On-line for on-line. The fourth field indicates the amplifier’s fault status:
FLT to indicate a fault (see line one of the OPS menu for the detailed fault descrip-
tion) or <blank> for no summary faults.
Remote Operation
Parallel Port
The only redundant function accessible from the parallel port is the capability to
monitor the position of the RF switch. Table 3-3 shows the proper sockets to moni-
tor on the parallel port. Switch 2 is not used in an HPAC 1:1 redundant system.
Serial Port
All functions available on the front panel are also available through the serial inter-
face. The mode of control on line 3 of the OPS menu must be set to “REM” or the
serial command, set control mode to remote, must be sent.
↓
→
←
+
−
> ops [STATUS] setup
P: 47.0 dBm
T: 35
°
C
LOC MAN Online
Attn: 00dB
Mute: OFF