73 av 82
OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023-03-16
@Pandrol 2023
Pump
P1
Flow L/min
17
System pressure
215 Bar
Flow measurement procedure.
Fillowing conditions to be fulfilled:
1.
Take appropriate precautions to not contaminate the fluid. Clean areas and surfaces of
where the test equipment shall connect to the hydraulic system.
2.
Use a flowmeter, manometer och flow restrictor classified for the specific pump flow and
pressure. Make sure that the test equipment is calibrated to give the correct values.
Pressure test:
Connect a pressure gauge to the quick coupler. Start the engine and run at maximum speed.
Check the pressure value given and compare with the table below.
Flow test:
Connect the flow meter to the quick couplers Anslut flödesmätaren till snabbkopplingarna. Start
the engine and run at maximum speed. Check the flow value given and compare with the table
below.
If the flow measured is 90% or higher than specification, the hydraulic pump is in good condition.
11.10. Brake pads
Use a calibrated measurement device to measure thickness of the brake pads.
Replace if the thickness of the brake pad is less than 2 mm.
11.9.
Hydraulic pressure and flow – Test
Pressure and Flow specification
Summary of Contents for CD200 IQ
Page 2: ...2 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Page 53: ...53 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Page 80: ...80 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Page 81: ...81 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...