8.1.2. Clipping
1. Make sure all settings described in previous chapters
are performed
2. Set the machine to manual operation by pressing the
button (2).
3. Set the tool to clipping mode by pressing the button
(1).
4. Position the work head centered above the clip
assembly.
5.
Pull and hold the dead man’s grip (7)
6. Press an hold the button (5) to operate the clipping
function.
7. Push the button (6) to retract the clipping arms.
8. Ensure that there is no damage to neither clip or
insulators.
9. Set the machine to auto clipping mode by pressing
the button (2). on the user panel.
10. Bring the machine to the next sleeper. Initiate a
clipping cycle by pressing the button (5). The clipping
arms will retract automatically.