6
FEATURES
PREFACE
The WJ-SX550C Matrix Switcher, when combined with the
optional WV-CU550C System Controller and WJ-AD550
Extension Unit, allows for flexible control of 128 cameras
and 16 monitors.
Tour and Group sequences for customized security
requirements can be easily established through the user-
friendly, on-screen menu setup.
Thanks to its modular construction, the WJ-SX550C allows
for flexible expansion to meet future needs.
The WJ-SX550C Matrix Switcher, when combined with the
WV-CU550C System Controller and WJ-AD550 Extension
Unit, enables control of the following functions:
• Routing of up to 128 cameras to any one of 16 moni-
tors.
• Remote control of up to 128 cameras and auxiliary
equipment by using optional receivers and acces-
sories, including:
1. Remote control of Pan-Tilt Head and Camera
Housing.
2. Remote control of Motorized Zoom Lenses: Focus,
Zoom and Iris.
3. Remote control of camera setting, including
Electronic Sensitivity Up, Electronic Shutter,
Electronic Zoom, and more.
Additional features of the WJ-SX550C include:
Versatile Camera Switching Modes
• Independent programmable sequence for each moni-
tor (16 programs)
• 32 tours including Dwell Time, Camera Preset Position
and Auxiliary Controls for any monitor.
• 8 group synchronized sequences including Dwell Time,
Camera Preset Positions and Auxiliary Controls
• Any tour or group synchronized sequence can be
selected by operators manually. If Alarm and Time
Event schedule are set up, the sequence activates
automatically.
Flexible Alarm Activation
• Alarm Mode 1: Any alarm is displayed on one designat-
ed monitor, and one associated Time Lapse VCR is
switched to real time mode.
• Alarm Mode 2: Any alarms are displayed on the four
designated monitors, and four associated Time Lapse
VCRs are switched to real time mode.
• Alarm Mode 3: Any alarms are displayed on any moni-
tors, together with sequence routines and presets.
Alternatively, any Tour or Group sequence can be
assigned to any monitor or group of monitors.
Programmable System Partitioning and Priority
• Operator Registration: 5 operator access levels to sys-
tem for setup and operation.
• Password protection to limit operators' access to sys-
tem.
• Operator priority to lock out access by lower priority
operators.
Summary of Contents for WVCU550C - SYSTEM CONTROLLER UNIT
Page 8: ...9 1 SECTION 1 FEATURES OF THE SYSTEM 500 MATRIX SWITCHER ...
Page 19: ...21 2 SECTION 2 DETAILED PRODUCT DESCRIPTION AND SELECTION ...
Page 45: ...47 3 SECTION 3 INSTALLATION AND SYSTEM CONNECTIONS ...
Page 61: ...65 4 SECTION 4 SOFTWARE SETUP ...
Page 90: ...95 5 SECTION 5 OPERATING PROCEDURES ...
Page 122: ...127 6 SECTION 6 TROUBLESHOOTING ...
Page 126: ...131 7 SECTION 7 SPECIFICATIONS ...