44
How to use the terminals of the ALARM/CONTROL connector
These terminals are used for emergency recording, auto time adjustment and when installing a buzzer, a lamp or a similar alarm
device.
The connector to be used should be compatible with the pin array.
Pin array
The pin array is different from other digital disk recorders. Make sure
that the connection is correct referring to the following.
Pin No.
Signal
Operation
Remarks
1
Alarm output 8
Alarm signal will be supplied at an event occur-
rence
Open collector output
24 V DC max., –100 mA
2
Alarm output 9
3
Alarm output 10
4
Alarm output 11
5
Alarm output 12
6
Alarm output 13
7
Alarm output 14
8
Alarm output 15
9
Alarm output 16
10
N/A
11
Alarm reset input
Canceling the alarm display
Non-voltage make contact
input/5 V pull-up
12
Emergency recording input
Starting emergency recording signal input
13
Signal ground
14
Signal ground
15
Available disk space warning
output
Signal output for available (remaining) disk space
warning of the normal recording area/event
recording area
Open collector output/
24 V DC max., –100 mA
16
HDD error output
Signal output upon detection of an HDD error
17
Camera error output
Signal output upon detection of a camera error
18
Error output
Signal output upon detection of a recorder error
19
Outage processing end
output
Signal output upon completion of outage pro-
cessing
High (+5 V to +12 V, max.
6.3 mA)
20
Time adjustment I/O
• According to the signal input from another
device, the time of this recorder will be adjust-
ed. (Slave)
• According to the signal output from the record
-
er, time of another device will be adjusted.
(Master)
Non-voltage make contact
input/30 kΩ, 5 V pull-up, Output
current –100 mA
21
Sequence switchover I/O
According to the signal input, the sequence
operation will be switched and the signal output
will be generated upon the sequence switchover.
22
Alarm suspension input
The state of the alarm suspension is assigned
according to the signal input.
Non-voltage make contact
input/5 V pull-up, –100 mA
23
Outage detection input
Start the outage processing according to the sig-
nal input.
24
External recording mode
switching input
Changeover to the external recording mode
25
+5 V output
+5 V output
200 mA max.
About the connectors
1
13
25
14
ALARM/CONTROL