100
[IP address]
When "Off" is selected for "DHCP", enter an IP address.
Enter 4 units from the decimal numbers (0-255).
Default:
192.168.0.250
[Subnet mask]
Enter a subnet mask according to the network environment
when "Off" is selected for "DHCP". Enter 4 units from the
decimal numbers (0-255).
Default:
255.255.255.0
[Default gateway]
Enter the IP address of the gateway according to the net-
work environment when "Off" is selected for "DHCP". Enter
4 units from the decimal numbers (0-255).
Default:
192.168.0.1
[Line speed]
Specify the line speed for data transmission.
Auto: Line speed will be applied automatically.
10M-Half: 10 Mbps half-duplex
10M-Full: 10 Mbps full-duplex
100M-Half: 100 Mbps half-duplex
100M-Full: 100 Mbps full-duplex
Default:
Auto
■
Maintenance port
The setting for the maintenance port behind the front panel
(operating section) of the recorder is configured.
This setting is required to maintain and support the recorder
from a PC connected via a network using the maintenance
port.
[IP address]
When "Off" is selected for "DHCP", enter an IP address.
Enter 4 units from the decimal numbers (0-255).
Default:
192.168.2.250
[Subnet mask]
Enter a subnet mask according to the network environment
when "Off" is selected for "DHCP". Enter 4 units from the
decimal numbers (0-255).
Default:
255.255.255.0
Important:
• The settings of "Network port" and "Maintenance port"
should be on a different subnet.
[Line speed]
Displays the line speed for data transmission.
It is impossible to change the setting value.