Item
Description
Description of
functions
When Execution Command (i_bEN) is turned ON, this FB executes the settings on the controller
specified by Set Controller (i_uSetController) in accordance with the value input to Write Lever
Ratio (i_uLeverRatio).
When Execution Command (i_bEN) is turned ON with Read Flag (i_bReadFlag) ON, however, the
lever ratios for all the connected controllers are output to Read Lever Ratio (o_u15ReadLeverRatio).
In this case, the values input to Set Controller (i_uSetController) and Write Lever Ratio
(i_uLeverRatio) are ignored and no setting takes place.
FB compilation
method
Macro type
FB behavior
Pulse execution type (multi-scan execution type)
i_bEN input condition None