SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
158/184
Error Code
Hexadecimal
(Decimal)
Description
Meaning
FB
be
ha
vi
or r
el
at
ed
e
rro
r c
od
es
200
(512)
Remote READY flag OFF
Check whether or not an error has occurred in the
communication unit. Check if the Start I/O
No.(i_uStartIONo) and the Station No.
(i_uStationNo) settings correctly indicate the target
communication unit.
201
(513)
Execution Command (i_bEN) turned OFF before
normal or error completion
Check that Normal Completion (o_bOK) or Error
Completion (o_bErr) has turned ON and then turn
OFF Execution Command (i_bEN). This error code is
output also when Execution Command (i_bEN) is
intentionally turned OFF before completion.
202
(514)
Execution Command (i_bEN) was turned from ON
to OFF and then turned from OFF to ON while
Execution Status (o_bENO) was ON
Check that Execution Status (o_bENO) turned OFF
and then turn ON Execution Command (i_bEN).
203
(515)
Input Signal (i_bInputSignal) is turned from OFF to
ON with Waiting Signal (o_bSignalWait) OFF
Check that Waiting Signal (o_bSignalWait) is ON
and then turn ON Input Signal (i_bInputSignal).
Teaching is not executed but the teaching operation
has been changed. Check for any problem.
FFFF
(65535)
Module error occurrence
Check the Module Error Code (o_ud16ModuleErrId).
For information on module error codes, see
"Appendix 2.4 Module error code
(o_u16ModuleErrId) list".