SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
131/184
Labels To Be Used
■ Input labels
Name
Variable name
Data type
Valid range
Description
Execution Command
i_bEN
Bit
ON, OFF
Turn ON this label to start the FB. You
can exit from the FB by turning it from
ON to OFF.
CC-Link IE Field flag
i_bIeFieldFlag
Bit
ON, OFF
Turn ON Execution Command (i_bEN)
with this flag OFF to start the FB on
SC-HG1-C or with this flag ON to start
the FB on SC-HG1-CEF.
Start I/O No.
i_uStartIONo
Word
[Unsigned]
Depends on the range of
the number of input/output
points of the target CPU
module. For more
information, refer to the
CPU User's Manual.
Specify in hexadecimal the number of
the starting I/O where the target
CC-Link/CC-Link IE Field
master/local module is installed. (For
example, specify H0A0 if the starting
I/O No. is 00A0.)
Station No.
i_uStationNo
Word
[Unsigned]
1 to 64 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is OFF
1 to 120 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is ON
Specify the station number of the
communication unit you want to
configure.
Set Eco Mode
i_bEcoModeSet
Bit
ON, OFF
If you turn Reset Flag (i_bReset) from
OFF to ON and execute this FB, it sets
the Eco mode.
Reset Flag
i_bReset
Bit
ON, OFF
Execute this FB with this label ON to
turn off the keylock and Eco mode.
Execute this FB with this label OFF to
turn on the keylock and set the Eco
mode in accordance with the value of
Set Eco Mode (i_bEcoModeSet) .