SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
82/184
Error code
■ List of error codes
Error code
(hexadecimal)
Description
Meaning
100
The Station No. (i_uStationNo) is
outside the valid range
For CC-Link master/local module
Set the Station No. (i_uStationNo) to a value from 1 to 64.
For CC-Link IE Field master/local module
Set the Station No. (i_uStationNo) to a value from 1 to 120.
101
The information derived from the input
Start I/O No.(i_uStartIONo) and the
Station No. (i_uStationNo) is not
SC-HG1-C or SC-HG1-CEF.
Check if the Start I/O No.(i_uStartIONo) and the Station
No. (i_uStationNo) settings correctly indicate the target
communication unit.
104
Set to a controller where Set Controller
(i_uSetController) is set to 0 or does not
exist
Make the value of Set Controller (i_uSetController) greater
than 0.
Check if the Start is not applied to a controller beyond the
maximum number of connected units. Also, check if the
15th bit of Set Controller (i_uSetController) is not ON.
200
Remote READY flag OFF
Check whether or not an error has occurred in the
communication unit.
Check if the Start I/O No.(i_uStartIONo) and the Station
No. (i_uStationNo) settings correctly indicate the target
communication unit.
201
Execution Command (i_bEN) turned
OFF before normal or error completion
Check that Normal Completion (o_bOK) or Error
Completion (o_bErr) has turned ON and then turn OFF
Execution Command (i_bEN). This error code is output
also when Execution Command (i_bEN) is intentionally
turned OFF before completion.
202
Execution Command (i_bEN) was
turned from ON to OFF and then turned
from OFF to ON while Execution Status
(o_bENO) was ON
Check that Execution Status (o_bENO) turned OFF and
then turn ON Execution Command (i_bEN).
FFFF
Module error occurrence
Check the Module Error Code (o_ud16ModuleErrId). For
information on module error codes, see "Appendix 2.4
Module error code (o_u16ModuleErrId) list".