Error code
(hexadecimal)
Description
Meaning
200
Remote READY flag OFF
Check whether or not an error has occurred in the
communication unit. Check if the Start I/O
No.(i_uStartIONo) and the Station No. (i_uStationNo)
settings correctly indicate the target communication unit.
201
Execution Command (i_bEN) turned OFF
before normal or error completion
Check that Normal Completion (o_bOK) or Error
Completion (o_bErr) has turned ON and then turn OFF
Execution Command (i_bEN). This error code is output
also when Execution Command (i_bEN) is intentionally
turned OFF before completion.
202
Execution Command (i_bEN) was turned
from ON to OFF and then turned from
OFF to ON while Execution Status
(o_bENO) was ON
Check that Execution Status (o_bENO) turned OFF and
then turn ON Execution Command (i_bEN).
203
Input Signal (i_bInputSignal) is turned
from OFF to ON with Waiting Signal
(o_bSignalWait) OFF
Check that Waiting Signal (o_bSignalWait) is ON and
then turn ON Input Signal (i_bInputSignal). Teaching is
not executed but the teaching operation has been changed.
Check for any problem.
FFFF
Module error occurrence
Check the Module Error Code (o_ud16ModuleErrId). For
information on module error codes, see "Appendix 2.4
Module error code (o_u16ModuleErrId) list".