![Panasonic PT-RQ32KU Operating Instructions Manual Download Page 237](http://html1.mh-extra.com/html/panasonic/pt-rq32ku/pt-rq32ku_operating-instructions-manual_4718480237.webp)
Chapter 7
Appendix — Technical information
ENGLISH - 237
Control details
Art-Net channel setting
[1]
[2]
[3]
[USER]
RASTER PATTERN
―
―
―
l
LENS H SHIFT MSB
―
―
―
l
*1
LENS H SHIFT LSB
―
―
―
l
*1
LENS V SHIFT MSB
―
―
―
l
*1
LENS V SHIFT LSB
―
―
―
l
*1
LENS FOCUS MSB
―
―
l
l
*1
LENS FOCUS LSB
―
―
l
l
*1
LENS ZOOM MSB
―
―
l
l
*1
LENS ZOOM LSB
―
―
l
l
*1
ENABLE/DISABLE
l
l
l
l
*1
These items can be controlled in following case.
When the standard DC motor unit installed in the Zoom Lens (Model No.: ET-D75LE6, ET-D75LE8, ET-D75LE10, ET-D75LE20, ET-D75LE30,
ET-D75LE40, etc.) is replaced with the stepping motor unit using the Stepping Motor Kit (Model No.: ET-D75MKS10), or when a projection lens with
the stepping motor is attached.
Control details
r
LIGHT OUTPUT
This can be set in 256 steps between 100 % and 0 %.
Performance
Parameter
Default value
100 %
0
0
…
…
0 %
255
r
INPUT SELECT (when [Art-Net CHANNEL SETTING] is set to [1])
Performance
Parameter
Default value
No operation
0-47
0
SDI1
48-55
SDI2
56-63
No operation
64-255