Lamp/Temperature/Filter Indicators
ENGLISH - 147
Maintenance
▶
■
Temperature indicator<TEMP>
Indicator
status
Lighting in red
Flashing in red
(2 times)
Flashing in red
(3 times)
Status
Warm-up status
Internal
temperature
is high.
(WARNING)
Internal temperature is high
(standby mode)
The cooling fan has
stopped.
Cause
z
Did you turn on the
power when the
room temperature
was about 0°C
(32°F)?
z
Is the air intake/exhaust port blocked?
z
Is the room temperature high?
z
Is the filter indicator <FILTER> not lit?
―
Solution
z
Wait at least five
minutes in the
current status.
z
Install the unit
in a location
with an ambient
temperature of
0°C (32°F) to 45°C
(113°F)
*1
.
z
Remove any objects that are blocking the air
intake/exhaust port.
z
Move the projector to a location with an
ambient temperature of 0°C (32°F) to 45°C
(113°F)
*1
and a humidity of 20% to 80% (no
condensation).
z
Clean the air filter unit or replace it. (
page 148)
z
Turn the <MAIN
POWER> switch to
<OFF> (
page 53),
and consult your
dealer.
*1: When using the projector at high elevations (1 400 m (4 593 ft) – 2 700 m (8 858 ft) above sea level), the operating environment
temperature will be 5°C (41°F) lower than the maximum limit. The upper limit of the operating environment temperature will be
reduced by a further 5°C (41°F) when using the replacement lamp unit (for portrait mode).
When using a smoke cut filter, the temperature will be 0°C (32°F) to 35°C (95°F). However, it cannot be used at high elevations.
Note
z
If the temperature indicator <TEMP> is still illuminating or flashing after taking the measures, ask your dealer
for repair.
▶
■
Filter indicator <FILTER>
Indicator
status
Lighting in red
Flashing in red
Status
The filter is clogged.
The temperature inside or outside the projector is abnormally high.
The air filter unit is not
attached.
Cause
z
Is the air filter unit
dirty?
z
Is the air intake/
exhaust port
blocked?
z
Is [HIGH ALTITUDE
MODE] set
correctly?
z
Is the air filter unit
attached?
Solution
z
Clean the air filter
unit or replace it.
(
page 148)
z
Remove any objects
that are blocking the
air intake/exhaust
port.
z
When using the
projector at high
elevations 1 400 m
(4 593 ft) – 2 700 m
(8 858 ft) sea
level, set [HIGH
ALTITUDE MODE]
(
page 103) to [ON].
z
Do not use the
projector at high
elevations 2 700 m
(8 858 ft) or higher
above sea level.
z
Attach the air filter
unit.
Note
z
If the filter indicator <FILTER> is still illuminating or flashing after taking the measures, ask your dealer for
repair.
z
[LAMP SELECT] may be set to [DUAL] when the filter clogged even when the [LAMP SELECT] is set to [QUAD]
or [TRIPLE]. Cleaning the air filter unit or replacing it with a new one will turn off the indicator.