[PROJECTOR SETUP] menu
106 - ENGLISH
Settings
▶
z
Setting [MODE] to [AUTO]
8) Press
▲▼
to select [LINK].
9) Press
◀▶
to switch [LINK].
▶
z
The setting will change as follows each time
you press the button.
[OFF]
[GROUP A]
[GROUP D]
[GROUP C]
[GROUP B]
[OFF]
Uses the luminance sensor on one
projector to perform correction without
connecting another projector.
The length of time that constant
brightness can be maintained increases
as the [BRIGHTNESS CONTROL
GAIN] value decreases.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Correction by luminance sensor is
performed by connecting several
projectors.
Use network functions to set up to four
A to D groups within the same subnet.
Up to eight projectors can be registered
and connected in each group.
10) Press
▲▼
to select [CHROMA
CORRECTION].
11) Press
◀▶
to switch [CHROMA
CORRECTION].
▶
z
The setting will change as follows each time
you press the button.
[OFF]
[ON]
[OFF]
Corrects only brightness.
[ON]
Corrects both brightness and color.
12) Press
▲▼
to select [CALIBRATION
TIME].
13) Press the <ENTER> button.
14) Enter the time and press the <ENTER>
button
▶
z
Measures brightness and color at the specified
time. Dynamic iris is fixed to open during
measurement.
15) Press
▲▼
to select [CALIBRATION
MESSAGE].
16) Press
◀▶
to switch [CALIBRATION
MESSAGE].
▶
z
The setting will change as follows each time
you press the button.
[ON]
[OFF]
[ON]
Displays a message during
calibration.
[OFF]
Does not display a message during
calibration.
17) Press
▲▼
to select [APPLY].
18) Press the <ENTER> button.
▶
z
The set [MODE] and [LINK] are enabled, and
LAMP RELAY screen alert is displayed when
the [LAMP RELAY] setting is [OFF]. When
[CALIBRATION MESSAGE] is set to [ON], a
calibration running message is displayed which
will automatically disappear 30 seconds after
calibration completes.
▶
z
If the <ENTER> button is pressed with [MODE]
in [BRIGHTNESS CONTROL SETUP] set to
other than [OFF], the brightness and color of
the lamp at the time the button was pressed is
recorded as a standard.
▶
z
If the <ENTER> button is pressed when [LINK]
is [GROUP A] to [GROUP D], the group name
is displayed on the projector screen set as the
same group.
/,1.
*5283$
Note
z
When setting the [MODE] in [BRIGHTNESS
CONTROL SETUP] to [AUTO] or [PC], [APPLY]
luminance control after the shutter is open for at
least two minutes.
z
If the shutter is closed within approx. 10 minutes
after the lamp has turned on while [MODE] in
[BRIGHTNESS CONTROL SETUP] is set to [AUTO]
or [PC], brightness and color cannot be measured.
Therefore, brightness may be corrected approx.
two minutes after the shutter opens.
z
When [MODE] in [BRIGHTNESS CONTROL
SETUP] is set to [AUTO] or [PC], brightness
and color of the lamp is automatically measured
eight minutes after the lamp has turned on, and
correction is performed so that the brightness and
color will be the same as a standard when [APPLY]
is performed. Brightness and color of the lamp
cannot be measured for eight minutes after the
lamp has turned on because they are not steady.
z
If the lamp turns off or lamp relay is performed
while the two or more lamps are selected in
[LAMP SELECT] and [MODE] in [BRIGHTNESS
CONTROL SETUP] is set to [AUTO], brightness
and color are corrected to the extent possible one
minute later.
z
When operating with [MODE] in [BRIGHTNESS
CONTROL SETUP] set to [AUTO], and [LINK] is
[OFF], brightness correction is performed until