Technical information
ENGLISH - 163
Appendix
Channel
Control details
Performance
Parameter
Remark
4
Lens control
Lens
adjustment
(-) High
speed
0-31
(-) Low
speed
32-63
(-) Fine
adjustment
64-95
Adjustment stop
96-127
Lens
adjustment
(+) Fine
adjustment
128-159
(+) Low
speed
160-191
(+) High
speed
192-223
Command performance
execute
224-255
5
Power supply control
Standby
0-63
No operation
64-191
Power on
192-255
6
Light volume adjustment
100 %
0
Can be set in 256 steps
between 100 % and 0 %.
…
…
0 %
255
7
Lock
Operation not available
0-127
When “Operation not
available” is set, operations
of all channels become
unacceptable.
Operation available
128-255
8
Fade-in time setting
0.0s
0-15
Operate together with channel
1.
0.5s
16-31
1.0s
32-47
1.5s
48-63
2.0s
64-79
2.5s
80-95
3.0s
96-111
3.5s
112-127
4.0s
128-143
5.0s
144-159
7.0s
160-175
10.0s
176-191
No operation
192-255