![Panasonic CZ-RTC4 Installation Instructions Manual Download Page 18](http://html1.mh-extra.com/html/panasonic/cz-rtc4/cz-rtc4_installation-instructions-manual_3842389018.webp)
18
Setting / Test operation / Speci
fi
cations
Setting
Clock
RC. setting mode (Main/sub, Clock type)
Detailed setting mode (Ventilation fan output
setting, Room temperature sensor, Temperature
display setting)
Clock
1
Press and hold
for several seconds.
2
Set day of the week, hour and minute.
→
“
▼
”: Su
Mo
…
Sa
(Repeat)
RC. setting mode
1
Press and hold the 2 buttons for several
seconds simultaneously.
A
,
2
Select the Code no.
3
Select the Set data.
→
The indicator illuminates after blinking.
Press
.
Code
no.
Item
Set data
0000
0001
01
Main/sub
Sub
Main
02
Clock type
24 hours
12 hours (AM/PM)
Detailed setting mode
1
Press and hold the 3 buttons for several
seconds simultaneously.
,
,
2
Select the Code no.
3
Select the Unit no.
4
Select the Set data.
→
The indicator illuminates after blinking.
Press
.
Code
no.
Item
Set data
0000
0001
31
Ventilation fan
output setting
Not connected
Connected
32
Room temperature
sensor
Main unit
RC
33
Temperature
display setting
°C
°F
Test operation
Turn on the circuit breaker beforehand, referring to
the operating instructions for the unit. The remote
controller starts.
1
Press and hold
for several seconds.
[TEST] display appears. (The unit enters the test
operation mode.)
2
Press
. Perform the test operation.
[TEST] is displayed during the test operation.
3
Press
. Finish the test operation
[TEST] display disappears.
4
Delete the error history.
Press and hold the 2 buttons for several
seconds simultaneously.
,
Information of errors is displayed.
To delete the error history, press
.
Press
to
fi
nish service mode.
Attention
• Do not use this mode for purposes other than the
test operation.
(To prevent overload of the units)
• Read the installation instructions supplied with the
units.
• Any of the Heat, Cool and Fan operations can only
be performed.
• Temperature cannot be changed.
• The test operation mode is automatically turned off
in 60 minutes. (To prevent continuous test operation)
• Outdoor units do not operate for approx. 3 minutes
after the power is turned on or operation is stopped.
Speci
fi
cations
Model No.
CZ-RTC4
Dimensions
(H) 120 mm × (W) 120 mm
× (D) 20 + 4.75 mm
Weight
160
g
Temperature/
Humidity range
0 °C to 40 °C / 20 % to 80 %
(no condensation) *Indoor use only.
Power Source
DC16 V (supplied with indoor unit)
Clock
Precision
± 30 seconds/month
(at normal temperature 25 °C)
*Adjust periodically.
Holding
time
24 hours
(when fully charged)
*Approx. 8 hours are required
for full charge.
Number of
connected
indoor units
Up to 8 units