004778250 - 30/03/2020
29
ENGLISH
Pag. 7/18
0CAR6IN019147
6.
MENU’
6.1
MAIN MENU
To enter into the main menu simply
click
on
K2
key:
➢
Keys
K3
and
K4
are used to scroll through various parameters signaled by the corresponding flashing led.
➢
Press
K2
key to modify (the led remains solid while value flashes).
➢
Keys
K3
and
K4
are used to change the parameter value.
➢
Press
K2
to save the new value.
➢
Press
K1
to exit without saving.
➢
Press
K1
again to exit the Menu or wait 30 seconds.
Led
Description
Code
Min
Set
Max
U.M.
Low Temp. Thermostat for Fireplace Pump
A01
20
50
90
[°C]
Diverting Valve Thermostat on Fireplace probe
A02
20
45
90
[°C]
Heating Pump Thermostat on Fireplace probe
A04
20
45
90
[°C]
Heating Pump Thermostat on high Buffer Tank probe
A17
20
45
90
[°C]
Service Thermostat on Fireplace probe
A09
20
50
90
[°C]
Valve Thermostat for DHW priority
A24
20
70
90
[°C]
Temperature Delta for Heating Pump enable
A83
2
10
20
[°C]
Thermostat to activate Integration on Fireplace probe
A03
20
45
90
[°C]
Thermostat Integration Buffer Tank on High Buffer Tank Probe
A19
20
45
90
[°C]
Thermostat Integration Boiler on Heating Return Probe
A25
20
50
60
[°C]
Heating Pump Thermostat on Fireplace probe
A04
20
45
90
[°C]
Service Thermostat on Fireplace probe
A09
20
50
90
[°C]
Heating Pump Thermostat on High Buffer Tank probe
A17
20
45
90
[°C]
S
2
DHW Boiler Thermostat on S2
A18
20
50
90
[°C]
Buffer Comfort Thermostat on High Buffer Tank probe
A20
20
60
90
[°C]
S
3
Ambient Probe Thermostat on S3
b01
5
20
50
[°C]
S
1+
S
3
Differential Thermostat Fireplace-Boiler DHW/Buffer
d01
5
20
2
[°C]
7. INSTALLER MENU
Only QUALIFIED PERSONEL must access this MENU
, because if the set parameters are changed this could make the
product completely unsuitable for the application.
➢
To enter into the INSTALLER MENU press at the same time
K2
and
K4
keys for 3 seconds.
➢
To scroll through the parameter codes use
K3
and
K4
keys.
➢
To view the value of a parameter and to enter modification mode press
K2
key.
➢
To modify the value press
K3
and
K4
keys.
➢
To save the new value press
K2
key.
➢
To exit without saving press
K1
key.
➢
Press
K1
again to exit the Menu or wait 60 seconds.
Description
Cod.
Min
Set
Max
U.M.
Thermostat to close Air Damper on S1 probe
A05
20
75
90
[°C]
ANTIFREEZE Thermostat on S1 probe
A06
-10
4
10
[°C]
SAFETY Thermostat on S1 probe
A07
60
80
90
[°C]
ALARM Thermostat on S1probe
A08
80
90
99
[°C]
Maximum Thermostat to enable heating pump
A11
20
75
90
[°C]
High Temp. Thermostat on high Buffer Tank probe
A23
20
95
95
[°C]
Solar Pump Activation Thermostat
A33
5
20
50
[°C]
ANTIFREEZE Thermostat on Collector Probe
A34
-10
4
10
[°C]
Collector Safety Thermostat
A35
60
120
180
[°C]
Collector Protection Thermostat
A36
60
140
180
[°C]
Temperature Delta for automatic management of PWM1 in Heating
A80
1
20
50
[°C]
Temperature Delta for automatic management of PWM1 in DHW
A81
1
15
50
[°C]
Temperature Delta for automatic management of PWM2 in Heating
A82
1
20
50
[°C]
Buffer-Collector Differentail Thermostat
d02
5
20
2
[°C]
Pressure Sensor Minimum threshold
Pr01
500
3000
500
[mbar]
Pressure Sensor Maximum threshold
Pr02
2000
3000
500
[mbar]
P1 Fireplace Pump Hysteresis Thermostat
IA01
0
2
20
[°C]
P2 Deviator Valve Hysteresis Thermostat
IA02
0
2
20
[°C]