004778250 - 30/03/2020
31
ENGLISH
Pag. 9/18
0CAR6IN019147
Percentage of PWM2 Duty Cycle in Antifreeze HEATING profile
U13
0
0
100
%
Percentage of PWM2 Duty Cycle in Safety HEATING profile
U14
0
0
100
%
Percentage of PWM2 Duty Cycle in Antiseize HEATING profile
U15
0
0
100
%
Percentage of PWM2 Duty Cycle in Modalità Manual HEATING profile
U16
0
0
100
%
Percentage of PWM2 Duty Cycle at Minimum Speed SOLAR profile
U21
0
15
100
%
Percentage of PWM2 Duty Cycle at Maximum Speed SOLAR profile
U22
0
95
100
%
Percentage of PWM2 Duty Cycle in Antifreeze SOLAR profile
U23
0
100
100
%
Percentage of PWM2 Duty Cycle in Safety SOLAR profile
U24
0
100
100
%
Percentage of PWM2 Duty Cycle in Antiseize SOLAR profile
U25
0
100
100
%
Percentage of PWM2 Duty Cycle in Manual Mode SOLAR profile
U26
0
50
100
%
Hydraulic Plant Configuration
ConF
17
1
17
n
Pag. 8/18
0CAR6IN019147
Boiler Integration Activation Hysteresis Thermostat
IA03
0
2
20
[°C]
Hysteresis Thermostat of Heating Pump on S1
IA04
0
2
20
[°C]
Hysteresis Thermostat to Close Air Damper
IA05
0
2
20
[°C]
ANTIFREEZE Hysteresis Thermostat
IA06
0
1
20
[°C]
SAFETY Hysteresis Thermostat
IA07
0
1
20
[°C]
ALARM Hysteresis Thermostat
IA08
0
1
20
[°C]
SERVICE output activation Hysteresis Thermostat
IA09
0
2
20
[°C]
Hysteresis Thermostat of Heating Pump enabling
IA10
0
2
20
[°C]
Hysteresis Thermostat of Heating Pump on Buffer probe
IA17
0
2
20
[°C]
Hysteresis Thermostat of DHW Boiler Thermostat on S2
IA18
0
2
20
[°C]
Hysteresis Thermostat of Integr. Buffer Tank on High Buffer Tank Probe
IA19
0
2
20
[°C]
Hysteresis Thermostat of Buffer Comfort on High Buffer Tank probe
IA20
0
2
20
[°C]
Hysteresis Thermostat of High Temp. on High Buffer Tank probe
IA23
0
2
20
[°C]
Hysteresis Thermostat of Valve for DHW priority
IA24
0
2
20
[°C]
Hysteresis Thermostat Integr. Boiler on Heating Return Probe
IA25
0
2
20
[°C]
Hysteresis Thermostat of Solar Pump Activation
IA33
0
2
20
[°C]
Hysteresis Thermostat of ANTIFREEZE Thermostat on Collector probe
IA34
0
1
20
[°C]
Hysteresis Thermostat of Collector Safety
IA35
0
2
20
[°C]
Hysteresis Thermostat of Collector Protection
IA36
0
2
20
[°C]
S3 Ambient probe Hysteresis Thermostat
Ib01
0
1
20
[°C]
Differential Hysteresis Thermostat Fireplace - Buffer
Id01
1
1
5
[°C]
Differential Hysteresis Thermostat S3-S2
Id02
1
1
5
[°C]
Differential Hysteresis Thermostat S1-S3
Id03
1
1
5
[°C]
Hysteresis Pressure Sensor Minimum threshold
IP01
0
50
400
[mbar]
Hysteresis Pressure Sensor Maximum threshold
IP02
0
50
400
[mbar]
Time on for ANTIFREEZE pump
t 01
1
5
300
[s]
Time off for ANTIFREEZE pump
t 02
0
30
300
[min]
SHOWER function time duration
t 03
0
10
120
[min]
ANTISEIZE time
“
on
”
of Pump
t 04
0
20
99
[s]
ANTISEIZE time “off”
of Pump
t 05
1
168
255
[h]
Delay time for Air Damper closure
t 06
0
10
120
[min]
Audible alarm suspension time
t 07
1
5
60
[min]
Type of Fireplace Probe
P01
0
0
2
n
Type of DHW Boiler/High Buffer Tank Probe
P02
0
0
2
n
Type of Low Buffer Tank Probe
P03
0
0
2
n
Type of Ambient Probe
P04
0
0
2
n
S3 Input Configuration
P05
0
0
5
n
SERVICE Output Configuration
P06
0
0
3
n
Enable Alarm Pressure Sensor
P07
0
0
1
n
Enable ANTIFREEZE on Fireplace Probe
P08
0
1
1
n
Enable ANTIFREEZE on Collector Probe
P09
0
0
1
n
Enable Boiler Integration Priority
P10
0
0
1
n
Enable Fireplace SAFETY Function
P11
0
1
1
n
Enable “Start” Function of Air Damper
P12
0
0
1
n
Enable SHOWER Function
P13
0
0
1
n
Enable ANTISEIZE of Pump1
P14
0
1
1
n
Abilitazione ANTISEIZE of Pump2
P15
0
0
1
n
Type of Collector Probe
P17
1
1
2
n
PWM1 Management
P18
0
0
2
n
PWM2 Management
P19
0
0
2
n
Flow switch thpe: 1=ON_OFF; 2 = Flow rate sensor management
P33
1
1
2
n
Corresponding value to twice of frequency according the Flow rate
P34
1
3
300
n
Percentage of PWM1 Duty Cycle at Minimum Speed HEATING profile
U01
0
85
100
%
Percentage of PWM1 Duty Cycle at Maximum Speed HEATING profile
U02
0
5
100
%
Percentage of PWM1 Duty Cycle in Antifreeze HEATING profile
U03
0
0
100
%
Percentage of PWM1 Duty Cycle in Safety HEATING profile
U04
0
0
100
%
Percentage of PWM1 Duty Cycle in Antiseize HEATING profile
U05
0
0
100
%
Percentage of PWM1 Duty Cycle in Manual Mode HEATING profile
U06
0
50
100
%
Percentage of PWM2 Duty Cycle at Minimum Speed HEATING profile
U11
0
85
100
%
Percentage of PWM2 Duty Cycle at Maximum Speed HEATING profile
U12
0
5
100
%