Single Pole (One location) or 3-Way (Multi-location)

Quiet Fan Speed Control

120VAC, 60Hz

Cat. No. IPFØ1-1L, 1.5A (Lighted)

INSTALLATION INSTRUCTIONS

DI-000-IPF01-02B

Tools needed to install your Fan Speed Control:

Slotted/Philips Screwdriver

Electrical Tape

Pliers

Pencil

Cutters

Ruler

Changing the color of your Fan Speed Control:

Your Fan Speed Control includes two color options. The Control ships with
the White frame attached. To change color of frame, proceed as follows:

Position the Slide Switch Shaft with the opening in the frame and line
up the plastic snaps with the square holes in the strap..

Installing Fan Speed Control by itself or with other
devices:

If installing Control in a single device application, proceed with the

INSTALLING YOUR FAN SPEED CONTROL

 section. If installing

Control in a multi-device application, proceed as follows:

MULTI-DEVICE APPLICATION:

NOTE: 

You only need to remove side sections if installing with other

controls or if it does not fit in wall box – not when installing with
mechanical switches.

NOTE:

 There is NO derating necessary for multi-gang installations of

this Fan Speed Control.

INSTALLING YOUR FAN SPEED CONTROL

NOTE: 

Use check boxes       when Steps are completed.

WARNING:

 

To avoid fire, shock, or death; 

TURN OFF

POWER

 at circuit breaker or fuse and test that power is off

before wiring!

Removing existing switch:

 

Remove existing

wallplate and switch mounting screws. Carefully pull switch
from wall box. 

DO NOT

 remove wires attached to the switch

at this time.

Identifying your wiring application (most
common):

NOTE:

 If the wiring in the wall box does not resemble any of

these configurations, consult a qualified electrician.

Step 2

Step 4

Step 1

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Single-Pole:

Look at the back of your switch.
If there are 2 wires connected to
two screw terminals (not
including a green or bare copper
wire used for grounding), you
have a Single-Pole switch.

Step 3
con’t

3-Way:

Look at the back of your switch.
If there are 3 wires connected to
three screw terminals (not including
a green or bare copper wire used
for grounding), you have a 3-Way
switch. Note that one of the
screw terminals will usually be a
different color (black) or labeled
Common. Tag that wire with
electrical tape to identify.

Tag Common

Screw Wire

Push in side at tab
to release

Line up tabs on back of
slider to switch shaft and
press in side to attach

WARNINGS AND CAUTIONS:

• To be installed and/or used in accordance with appropriate electrical codes and regulations.

• If you are unsure about any part of these instructions, consult a qualified electrician.

• To avoid overheating and possible damage to this device and other equipment, do not install to

control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance other than
appropriate ceiling fans.

• To reduce the risk of fire or electrical shock, this control is to be used with ceiling fans that are rated

120VAC, total load 1.5 amperes maximum.

WARNINGS AND CAUTIONS:

• For use on ceiling paddle fans with split-capacitor or shaded pole motors only. Please refer to

manufacture's instructions or rating label on the motor to confirm type. Use with any other types of
motors or equipment may cause overheating and/or damge to the motors or equipment.

• Use only one (1) Fan Speed Control per load. The switch(es) will turn ON the fan at the speed level

selected at the control.

• Disconnect power at circuit breaker or fuse when servicing fixture.

• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked

CO/ALR or CU/AL.

Bend back and
forth to remove side
section

Remove
all inner
side
sections

Do not
remove
outer
side
sections

Disconnect wires from screw terminals or
Quickwire™ slots (shown).

Pull off pre-cut insulation from Control leads.

Make sure that the ends of the wires from the
wall box are 

straight (cut if necessary)

.

Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).

For Single-Pole Application, go to Step 5A.

For 3-Way Application, go to Step 5B.

Strip 5/8"

Cut

(if necessary)

Press in slot and
pull out wire

Strip Gage

5/8"

Step 3

Disconnecting switch wires and preparing wires: