SECTION 4 - CONTROL COMPONENTS
4-16
31215825
2
Ancillary 1 Anti-Tie-down
0
0-1
2
Ancillary 2 Anti-Tie-down
0
0-1
2
Mode Select Delay
(active before time-out)
5 Sec.
0 - 60 Seconds
2
Invert Lift Direction
NO
YES/NO
2
Lift Lock Delay
5 Sec.
0 - 60 Seconds
2
Acceleration
(platform lowered)
80
1 - 100
2
Deceleration
(platform lowered)
80
1 - 100
2
Turn Acceleration
(platform lowered)
50
1 - 100
2
Turn Deceleration
(platform lowered)
50
1 - 100
2
Maximum Forward Speed
(platform lowered)
100
1 - 100
2
Minimum Forward Speed
(platform lowered)
40
1 - 100
2
Maximum Reverse Speed
(platform lowered)
50
1 - 100
2
Minimum Reverse Speed
(platform lowered)
20
1 - 100
2
Maximum Turn Speed
(platform lowered)
20
1 - 100
2
Minimum Turn Speed (
platform lowered)
15
1 - 100
2
Minimum Forward Speed
(platform elevated)
13
1 - 100
2
Minimum Reverse Speed
(platform elevated)
13
1 - 100
2
Minimum Turn Speed
(platform elevated)
5
1 - 100
2
Motor Compensation
50 mOhms
0 - 500 mOhms
2
EPPROM Reset
—
Resets GCM to default factory settings
Notes:
(a) MSP Models equipped with stock-picker platform and mid-gate interlock (drive inhibit) switch are factory preset to HIGH.
(b) MSP Models equipped with 12 ft. or 14 ft. lift-limit-switch option are factory preset to HIGH.
Table 4-1. MVL/MSP Ground Control Module - Field Programmable Settings and Factory Preset
Level-2:
Service Level Settings
On LCD Display:
YES =
HIGH =
Level-3:
Operator Level Settings
NO =
LOW =
LEVEL
PROGRAMMABLE ITEM
FACTORY PRESET
SETTING RANGE
Go to
Discount-Equipment.com
to
order your