SECTION 6 - TROUBLESHOOTING
6-32
31215825
NOTE:
In the procedures below, if you check continuity between pin 6 and 16 it should show open circuit, when the platform gates are closed
and nothing is on the foot switch. When you step on the foot switch with the gates closed, you should see a closed circuit.
Table 6-34. Code 34 - P2-Auxiliary #1 - Inhibit
STEP
ACTION
SPEC
YES
NO
1.
At the Ground Control Module, P2 connector, check the voltage
across pins-16 (orange/red 49-5) and 6 (black 12) is reading within
specification?
0 - 2V DC
Go to Step 2
Replace Ground
Control Module
2.
Remove the P2 connector from the Ground Station Module; check
continuity of the individual wires in the platform harness. (
P2 to plat
-
form junction box
),
—
Go to Step 3
Repair or
Replace Platform
Harness
3.
Check continuity of gate switches and foot-switch circuit.
(
Switches
are wired in series; doors shut and foot switch depressed, circuit will be
closed)
Consult Factory
Replace Compo
-
nent or Repair
Wires