For Ukrainian providers the number is as follows: "
380676663377
" ("Kievstar").
An example for Russian providers – "
780936663377
".
The response of the Control Panel is as follows:
If the number of calling phone coincides with the
frst
phone number
(located in the frst cell
of the SIM-card) –
Control Panel is armed forcibly,
regardless of its status (armed or disarmed) and
zones status (violated or not). Then, the Control Panel sends "
Arming
" message to "Orlan" CMS. If any
zone has been violated while such arming, the alarm codes of violated zones are transmitted as
well.
If the phone number coincides with the
second
phone number
(the second cell of the SIM-
card) –
Control Panel deactivates AUX output for a certain period (confgurable).
Then, the Control
Panel sends "
AUX
r
emote deactivation
" to CSM.
If the phone number coincides with the
third
phone number
(the third cell of the SIM-card) –
Control Panel enables arming
and sends
"Object status report"
to CMS (object status is not changed
in this case):
●
If Control Panel is armed and none of zones is violated, "
Armed with no alarms
" report is
sent.
●
If Control Panel is armed with one or several violated zones, "
Armed with alarms
" report
is sent.
●
If Control Panel is not armed and none of 24-hour zones is violated, a "
Not armed with no
alarms
" report is sent.
●
If Control Panel is not armed with a violated 24-hour zone or violated zones, "
Not armed
with alarms
" report is sent.
If the phone number coincides with the
fourth
phone number
(the fourth cell of the SIM-card)
–
arming prohibition is activated,
and "
Arming prohibited
" message is sent to CMS.
When attempting to arm the Control Panel with a key, LEDs of the reader will fash several
times and go out, and the Control Panel will not be armed.
Note. If the phone number of the corresponding control function is not inputed in the
relevant cell of the SIM-card (i. e. it is empty – for example, the frst cell), the relevant
function will not be active (in this example, it is the forced arming).
12. Battery monitoring arrangement
The battery monitoring function is enabled by default and runs automatically.
13. Arrangement of main power supply monitoring (230V)
The board of “Lun-7T” Control Panel has a main power supply control contact 230V –
АСТ
. When
using UPS manufactured by
Ortus Group
for powering of “Lun-7T” Control Panel, the control is
provided by means of the built-in sensor with
АСТ
output (see Figure 7).
БААИ.425523.003ИУ
Rev. en_19
19