ZONE 2
– Discharged battery;
ZONE 3
– GSM channel glitch;
ZONE 4
– Local bus trouble when network expanders are connected;
ZONE 5
– Not sent events available.
1.
Prime power fault (230V)
–
AC230V
LED is OFF,
SYSTEM
LED fashes frequently,
ZONE 1
LED is lit when
TROUBLE
button is pressed and held.
When the prime power supply is recovered, AC 230V is ON.
2.
Discharged battery (Alternative power fault)
– occurs when there is no battery connected or
if the battery is discharged. In this case,
BATTERY
LED extincts and
SYSTEM
LED fashes
frequently (with the interval of 0.26, duration – 0.13 sec), and
ZONE 2
LED is lit when
TROUBLE
button is pressed and held.
When the charged battery is connected or after the battery has been charged,
BATTERY
LED
is ON.
3.
General fault
is displayed by frequent fashing of
SYSTEM
and
AC230V
LEDs, and indication
of the “running fre” type of
ZONE 1…8
LEDs (LEDs fash and extinct fast one by one). This
trouble is indicative of loss of connection between the Control panel and “Lind-7” ICD for
more than 6 seconds, or disability of the Control Panel.
4.
GSM channel glitch (ATS fault)
is displayed by frequent fashing of
SYSTEM
LED and lighting
up of
ZONE 3
LED when
TROUBLE
button is pressed and held.
5.
Local bus trouble
is displayed by frequent fashing of
SYSTEM
LED and glowing of
ZONE 4
LED when
TROUBLE
button is pressed and held. This fault shows that there has been no
connection between the Control Panel and any of the following network devices: "Lun-5N",
"Lun-7N', "Lun-73N" within up to 6s.
9.1.4. Arming
1. To arm the facility, you shall shut all the doors and windows equipped with detectors.
Attention! If at least one detector (zone) is alarmed, the facility shall not be armed.
When the authorized electronic key touches the reader, ARMED LED will fash shortly
without any sound a few times and extinct. Number of fashes (1…8) indicates the number
of the detector (zone) alarmed. If there are 9 fashes, it means that arming is prohibited.
In case “Lind-7” ICD is in the area of coverage of the optical detector, you shall stop and stand
still until the detector is in the normal state.
When all detectors are recovered,
ZONE 1…8
LEDs are not lit.
Attention! In case all LEDs of ZONE 1…8 do not extinct, RESET button shall be
pressed. If even after doing this LEDs do not extinct, the mounting of wires and zones and
status of the detectors shall be checked.
2. When all LEDs of
ZONE 1…8
of “Lind-7” ICD are lit off, you shall touch Touch Memory key
reader with the correct authorized electronic key.
БААИ.425523.003ИУ
Rev. en_19
10