SYSTEM
(yellow LED) – informs about failure of the internal program of device;
READY
(green LED) –
blink
while the Control Panel is disarmed,
off
– in the armed state;
POWER
(green LED) – informs of ICD power supply status;
ACCESS LEVEL
(yellow LED) – informs a user on which level he/she is when using ICD.
Action buttons functions:
MEMORY
Single pressing of the button displays (within 30 s) the zones activated within the
armed period.
Active for any user.
MUTE
Single pressing of the button induces a temporary deactivation of the built-in
sounder. The sounder is enabled automatically when new events occur.
Active for any user.
SIGNAL
LEVEL
Single pressing of the button initiates displaying of the signal level (within 30 s) by
ZONE 1…8 LEDs. The more LEDs are lit, the higher the signal level is.
TEST INDIC.
When the button is pressed, the power is supplied to all LED indicators of "Lind-9"
to control their operability.
Active for any user.
Single pressing of this button cancels the commands inputted on the keypad
"Lind-9" has a built-in buzzer.
If the device is connected, pressing of any key is accompanied by a beep (one pressing – one
beep).
If there is no Control Panel connection, pressing of any key (except
MUTE
and
TEST INDIC.
) on
the keypad is accompanied by a muffe beep.
Acceptance to execution of any command (correct password entry or available command
input) is confrmed by the series of beeps.
Input of an incorrect command (except
MUTE
and
TEST INDIC.
) on the keypad is accompanied
by a long signal.
The uncovered backside of ICD has the terminals for connection to the Control Panel (see
Table 4and Figure 20).
Table 4. Functions of "Lind-9" ICD terminals
Contact
Functions
GND
Common contact (–) of device
BUS
Connection of Control Panel contact (TM)
+12V
Device power 12V
БААИ.425523.003ИУ
Rev. en_19
13