12 Sample programs
-
109
-
12.3 Speed change operation at a specified time
Sample sequence program
[1] PULSE1 2
Sets the pulse output mode to 2-pulse mode
[2] T1 30.0
Sets the acceleration/deceleration rate to
30 ms/kHz
[3] VS1 500
Sets the starting speed to 500 Hz
[4] V1 1000
Sets the operating speed to 1000 Hz
[5] H1 +
Sets the rotational direction to CW
[6] SCAN1
Execute continuous operation
[7] DELAY 1
Sets the delay to 1 second
[8] V1 2000
Sets the operating speed to 2000 Hz
[9] DELAY 2
Sets the delay to 2 seconds
2000 Hz
1000 Hz
500 Hz
1 s
2 s
To stop a continuous operation, enter an S command or turn the S-STOP input on.