Identify and Remove a Faulty Processor
3.
Using a Torx T30 screwdriver, loosen the four captive nuts that secure the
processor-heatsink module to the socket: fully loosen nut 4, then 3, then 2, then
1. [1]
4.
Lift the processor-heatsink module from the socket [2].
Always hold the processor-heatsink module along the axis of the fins to prevent damage.
5.
Separate the processor from the heatsink.
140
Oracle Server X7-2 Service Manual • October 2017