Interpreting LEDs
No.
LED or Control
Description
4
Power Button
See
“Removing Power From the Server” on page 45
(System Power Button)” on page 160
5
SP OK indicator
Indicates these conditions:
■
Off
– AC power might not have been connected to the power supplies, or an SPM
error has occurred and service is required.
■
Steady on
– SP is running in its normal operating state. No service actions are
required.
■
Slow Blink
– SP is initializing the Oracle ILOM firmware.
6
Fan Module Fault LED (amber)
Indicates these conditions:
■
Off
– Steady state, no service action is required.
■
Steady on
– A fan module failure event has been acknowledged and a service action
is required on at least one of the fan modules.
7
Server Power Supply Fault LED
(amber)
Indicates these conditions:
■
Off
– Steady state, no service action is required.
■
Steady on
– A fault has been detected on one of the two power supplies.
8
Server Overtemp LED (amber)
Indicates these conditions:
■
Off
– Steady state, no service action is required.
■
Steady on
– A temperature failure event has been acknowledged. A temperature
limit has been exceeded, and a service action is required.
Related Information
■
“Rear Panel Controls and LEDs” on page 30
■
“Checking for Faults” on page 21
Detecting and Managing Faults
29
Summary of Contents for SPARC T8-1
Page 1: ...SPARC T8 1 Server Service Manual Part No E80510 04 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 1 Server Service Manual January 2022 ...
Page 20: ...20 SPARC T8 1 Server Service Manual January 2022 ...
Page 58: ...58 SPARC T8 1 Server Service Manual January 2022 ...
Page 106: ...106 SPARC T8 1 Server Service Manual January 2022 ...
Page 112: ...112 SPARC T8 1 Server Service Manual January 2022 ...
Page 128: ...128 SPARC T8 1 Server Service Manual January 2022 ...
Page 146: ...146 SPARC T8 1 Server Service Manual January 2022 ...
Page 152: ...152 SPARC T8 1 Server Service Manual January 2022 ...