Verify SP Functionality
Unrecognized Chassis: This module is installed in an unknown or
unsupported chassis. You must upgrade the firmware to a newer
version that supports this chassis.
Note -
Whenever you replace the SP or the motherboard, update the firmware on the server so
the portions of firmware in the two components remain consistent.
5.
Configure the SP NET MGT port so that it can access the network, and log in to
the SP through the NET MGT port.
Refer to
Servers Administration
or the Oracle ILOM documentation for network configuration
instructions.
6.
Download the system firmware.
Follow the firmware download instructions in
Servers Administration
or the Oracle ILOM
documentation.
Note -
You can load any supported system firmware version, including the firmware version
that was installed prior to replacing the SP.
7.
If you created a backup of your Oracle ILOM configuration, use the Oracle ILOM
restore utility to restore the configuration of the replacement SP.
Refer to the Oracle ILOM documentation for instructions.
8.
Power on the server.
“Power On the Server (Oracle ILOM)” on page 172
.
9.
Verify the SP.
“Verify SP Functionality” on page 133
.
Related Information
■
Oracle ILOM documentation
■
■
“Verify SP Functionality” on page 133
Verify SP Functionality
1.
Verify that the SP Status LED is illuminated green.
Servicing the SP
133
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...