Install the Battery
2.
Attach an antistatic wrist wrap and unpack the replacement battery.
3.
Press the new battery into the battery holder with the positive side (+) facing
away from the metal tab that holds it in place.
If the SP is configured to synchronize with a network time server using NTP, the Oracle ILOM
clock will be reset as soon as the server is powered on and connected to the network. Otherwise,
proceed to the next step.
4.
If the SP is not configured to use NTP, you must reset the Oracle ILOM clock
using the Oracle ILOM CLI or the web interface.
For instructions, see the Oracle ILOM documentation.
5.
Return the server to operation.
a.
Return the server to the normal operating position.
“Return the Server to the Normal Operating Position” on page 170
b.
Reinstall the power cords to the power supplies and power on the server.
“Returning the Server to Operation” on page 169
Related Information
■
“Remove the Battery” on page 117
Servicing the Battery
119
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...