Install the Motherboard
See
“Attach Power Cords” on page 172
.
18.
Prior to powering on the server, connect a terminal or a terminal emulator (PC or
workstation) to the SP through the SER MGT port.
Refer to
Server Installation
for instructions.
The SP detects the host firmware on the replacement motherboard is not compatible with the
existing service processor firmware, further action will be suspended and the following message
will be displayed:
Unrecognized Chassis: This module is installed in an unknown or
unsupported chassis. You must upgrade the firmware to a newer
version that supports this chassis.
Note -
Whenever you replace the motherboard or the SP, update the firmware on the server so
the portions of firmware in the two components remain consistent.
19.
Prepare to download the system firmware.
If necessary, configure the server's NET MGT port so that it can access the network. Log in to
the SP through the NET MGT port.
Refer to the Oracle ILOM documentation for network configuration instructions.
20.
Download the system firmware.
Follow the firmware download instructions in the Oracle ILOM documentation.
Note -
You can load any supported system firmware version, including the firmware version
that was installed prior to replacing the motherboard.
21.
If necessary, reactivate any RAID volumes that existed prior to replacing the
motherboard.
If your server contained RAID volumes prior to replacing the motherboard, see
for instructions.
22.
Power on the server.
See
“Power On the Server (Oracle ILOM)” on page 172
23.
(Optional) Transfer the serial number and product number to the FRUID of the
new motherboard.
If the replacement motherboard must have the same serial number as the server prior to
servicing, trained service personnel must take this action in a special service mode.
152
SPARC T5-2 Server Service Manual • February 2017
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...