Power On the Server (Power Button)
Power On the Server (Power Button)
Caution -
Do not operate the server without all fans, component heat sinks, air baffles, fillers,
and the cover installed. Severe damage to server components can occur if the server is operated
without adequate cooling mechanisms.
1.
Verify that the power cords are connected and that standby power is on.
Shortly after power is applied to the server, the SP OK/Fault LED blinks as the SP boots. The
SP OK/Fault LED is illuminated solid green when the SP has successfully booted. After the SP
has booted, the Power OK/LED on the front panel begins flashing slowly, indicating that the
host is in standby power mode.
2.
Press and release the recessed power button on the server front panel.
FIgure
Legend
1
Power/OK LED
2
Power button
3
SP OK Fault LED
When main power is applied to the server, the main Power/OK LED begins to blink more
quickly while the server boots and lights solidly once the operating system boots.
Each time the server powers on, POST can take several minutes to complete tests.
Related Information
■
“Power On the Server (Oracle ILOM)” on page 172
Returning the Server to Operation
173
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...