background image

Dell T130 Honeywell Server Planning, Installation and

Service Guide

HWDOC-X450-en-D

November 2019

Summary of Contents for MZ-PCSV74

Page 1: ...Dell T130 Honeywell Server Planning Installation and Service Guide HWDOC X450 en D November 2019 ...

Page 2: ...al Sàrl While this information is presented in good faith and believed to be accurate Honeywell disclaims the implied warranties of merchantability and fitness for a purpose and makes no express warranties except as may be stated in its written agreement with and for its customer In no event is Honeywell liable to anyone for any direct special or consequential damages The information and specifica...

Page 3: ... slot requirement 13 2 4 2 FTE supervisory Default 13 2 4 3 Cnet configuration using PCIC interface 13 2 5 Memory configuration for Dell T130 13 2 5 1 8 GB consisting of two 4 GB ECC DDR4 UDIMM 2133 MHz or faster 13 2 6 System specifications 14 2 6 18 Hard disk drive specifications 19 2 6 19 Removable media specifications 19 2 6 20 Storage and media devices 19 2 6 21 Mouse and keyboard 20 2 6 22 M...

Page 4: ...etwork 30 4 2 2 MAU connection 30 4 2 3 ControlNet Network 30 4 3 Configuring ControlNet interface card 31 4 3 1 Installing ControlNet card inside Magma chassis 31 Chapter 5 Servicing 33 5 1 Removing the Side Cover 33 5 2 Servicing the hard disk drives and power supply 34 5 3 Servicing Honeywell options 35 5 3 1 Slot requirements for General Ethernet and FTE node setup 35 5 4 Adding additional mem...

Page 5: ...valent nodes and overall system features architecture will differ from that of a non ELCN integrated system classic LCN TPN system In this case it may be necessary to refer to appropriate ELCN documentation in addition to the information provided herein NOTE If the Local Control Network LCN coaxial based system has been integrated with an Experion Fault Tolerant Ethernet FTE based system the node ...

Page 6: ...hernet Installation and Service Guide EPDOC XX36 en510A FTE system installation servicing troubleshooting Universal Embedded Appliance Hardware Installation and Maintenance Guide HWDOC X469 en A General UEA planning installation and service information before it is commissioned as an ELCN appliance Integrated Experion TPS User s Guide EPDOC XX66 en 510A Supplementary installation tasks needed befo...

Page 7: ...d connecting them into plant IT networks Experion R510 Software Change Notice EPDOC X166 en 510A Describes Experion R510 features enhancements overall product release interoperabilities system dependencies problem resolutions known issues special considerations Customer Release Guide R687 CRG 687 TPN TPS Migration information ELCN migration Information included TPN R687 Software Change Notice TNDO...

Page 8: ... Honeywell engineering has tested theDell PowerEdge T130 serverwith other Honeywell hardware and software and has qualified its use for specific configuration items as identified in the Software Change Notice SCN This server is not a standard Dell model and cannot be ordered independently from Dell The Technical Assistance Center TAC is well trained and supports Honeywell platforms Use of any othe...

Page 9: ...entified in the following table Model number Description MZ PCSV74 Intel Xeon E3 1220 v5 3 0 GHz 8M Cache 16 GB UDIMM 2x8 GB 500 GB or 1 TB SATA Hard disk drive QTY 1 EP COAR28 Windows Server 2008 R2 COA EP COAS16 Windows Server 2016 COA 2 2 2 Electronics configuration The Dell T130 based server is approved for installation in 800 and 1000 mm deep Honeywell LCN cabinets using either a fixed mounti...

Page 10: ...Intel Xeon E3 1220 v5 3 0 GHz CPU 8 GB UDIMM 2x4 GB 500 GB SATA Hard disk drive l Rear Ports 1 serial 1 Video 2 USB V2 0 2 USB3 0 2 RJ45 1 ID push button with blue amber LED l Front Ports 2 USB 2 0 ID push button with blue amber LED 1 system power on off button l Broadcom 5720 1GbE Dual Port Ethernet NIC with failover and load balancing l Bus Type PCIe l Expansion slots 4 PCIe slots o One full hei...

Page 11: ...to PCI convertor box 2 2 7 Power cords The following table lists the AC power cords Part description Part number AC power cord 220 V 51305557 100 2 3 Platform information l Honeywell documentation l Dell documentation 2 3 1 Honeywell documentation The following table lists the Honeywell publications that may be useful when installing or operating your system Publication Contains information about ...

Page 12: ... Systems Hardware Owner s Manual Removing and replacing the parts Technical specifications Configuring the system Troubleshooting Product Documentation CD www dell com Rack Installation Instructions Sliding Rails Installing the server in a server rack or cabinet Packaged with the computer www dell com Windows Installation Instructions and Important Information Initialization the Windows operating ...

Page 13: ...oes not support PCIC interface you must use Magma PCIe to PCI converter box Slot number Description Option Slot 1 PCIe x 8 CPU Magma PCIe host card Slot 2 PCIe_G3 x 16 CPU Slot 3 PCIe_G3 x1 PCH Slot 4 PCIe_G3 x 8 PCH 2 5 Memory configuration for Dell T130 Standard memory for Dell T130 server are 51156307 100 8GB 2x4GB DDR4 UDIMM 2133 MHz or faster and 51156307 200 16GB 2x8GB DDR4 UDIMM 2133 MHz or...

Page 14: ... UDIMM 1 A4 2 6 System specifications 2 6 1 Microprocessor Microprocessor Tab 100 Tab 200 Skylake Intel Xeon E3 1220V5 3 0 GHz 8M cache 8GT s Intel Smart Cache 8 MB Chipset Intel C236 series chipset PCIe slots 3 PCIe slots 1x8 PCIe 3 0 x16 connector 1x4 PCIe 3 0 x8 connector 1x1 PCIe 3 0 x1 connector 14 ...

Page 15: ...DIMM DDR4 2133 MHz or faster Maximum RAM l Tab 100 16 GB 4 x 4 GB UDIMM DDR4 2133 MHz or faster l Tab 200 32 GB 4 x 8 GB UDIMM DDR4 2133 MHz or faster 2 6 3 Raid controller RAID controller Not Applicable 2 6 4 Optical disk drive DVD drive SATA DVD R W 2 6 5 Video Video type Matrox G200 Controller 2 6 6 Network interface Adapter type On Board LOM 1GBE Dual Port BCM5720 GbE LOM 2 6 7 Power The follo...

Page 16: ...iously are for sea level An altitude derating of 1 C per 300 m 1 8 F per 1 000 ft to 3048 m 10 000 ft is applicable Direct sunlight is not allowed Operating humidity 10 to 80 Relative Humidity with 29 C 84 2 F maximum dew point Storage humidity 5 to 95 RH with 33 C 91 F maximum dew point Atmosphere must be non condensing at all times ATTENTION Storing maximum humidity of 95 is based on a maximum t...

Page 17: ...A S71 01 1985 Environmental Conditions for Process Measurement and Control Systems Temperature and Humidity ANSI ISA S71 04 1985 Environmental Conditions for Process Measurement and Control Systems Airborne Contaminants 2 6 9 Physical form factor Height 363 3 mm with rubber pads Width 175 mm Depth 454 mm Weight Maximum Config 11 5 kg 25 35 lbs 2 6 10 Drive bays Internal Up to 4 x 3 5 HDD External ...

Page 18: ...m allowable altitude change rate is 457 m min 1500 ft min that is 1 F 167 64 meters that is 17 22 C 167 64 meters Storage 12 000 m 39 370 ft Maximum allowable altitude Change rate is 457 m min 1500 ft min 2 6 14 External peripherals Keyboard Windows compliant USB equivalent or better Mouse USB equivalent or better 2 6 15 Drives Hard Drive Tab 100 Tab 200 500 GB 7 2K RPM SATA 3 Gbps 3 5 Cabled Hard...

Page 19: ...atts 10 8 Other DC POWER 9 5 W Watts Max 8 75 W Watts idle AC Power N A The following table provides the maximum weight and dimensions for 500 GB hard drive Description Requirement Height 19 98 0 787 mm inch Width 101 6 4 0 mm inch Depth 146 99 5 787 mm inch Weight 415 0 92 gms lbs 2 6 19 Removable media specifications The Honeywell based Dell T130 server has one SATA DVD RW drive The SATA DVD RW ...

Page 20: ... display generator defaults to a resolution which precludes communication with the system software and stops startup To determine if a cable is DDC compatible ensure that pins 5 9 and 12 of the HD15 connector are wired The IS supplied cable 51196742 200 is DDC compatible 2 7 Industrial regulatory compliance The compliance specifications in this section apply to cabinet installations WARNING Honeyw...

Page 21: ...001 Am 2 l IEC 61010 1 2001 2nd edition ATTENTION In the above referenced standards is a Normative Reference section citing additional standards which may apply as suited and required for product compliance 2 8 Light industrial regulatory compliance The compliance specifications in this section apply to installations other than cabinets ATTENTION Honeywell does not claim Safety Compliance or Elect...

Page 22: ...he Portable Transceivers walkie talkies in Watts Examples P 10 Watts D 0 949 meters P 5 Watts D 0 671 meters P 1 Watt D 0 300 meters Electrical cables which are routed external to the equipment must be fully shielded cables 360 degree metallic shielding to comply with the above EMC standards 2 8 2 Safety compliance The following are the light industrial regulatory product safety compliance l CSA C...

Page 23: ...nstallation Guide SW20 600 Starting the server l Before you begin 3 1 1 Before you begin Ensure that you perform the following tasks l Ensure that the cabinet is properly grounded l Unpack the platform from the box and verify the parts l Place the server on a secure surface near the cabinet to mount l Ensure that you have the necessary cables ready 3 2 Power and grounding requirements The ground c...

Page 24: ...ter deep Honeywell MP C1MCB1 cabinet The server must be mounted on rack space interval 11U through 15U counting from the bottom of the cabinet and moving up Install a 1U air duct baffle and blank front panel in the rails directly above the server The room ambient temperature must be kept between 10 dm and 30 dm C 50 dm to 86 dm F 3 3 1 Unused cabinet spaces ATTENTION To ensure proper computer cool...

Page 25: ...he server in either 800 or 1000 millimeter mm deep LCN cabinets model number MP C8LCB1 Tab and MP C1MCB1 Tab respectively This procedure assumes that a new 800 or 1000 mm deep cabinet was shipped from the Honeywell factory with either the fixed rail mounting kit model number TP SPCMF1 or the slide tray mounting kit model number TP SPCMS1 pre installed l Honeywell_server_back_panel_connections_T130...

Page 26: ...2 Connect the Honeywell AC power cords 3 Perform any one of the following as necessary l If you are not using Fault Tolerant Ethernet FTE connect the Ethernet cable to the on board RJ 45 connector l If you are using an Intel dual NIC card for FTE connect the FTE cable to the NIC card in the expansion slot l If you are using the on board NICs for FTE connect the FTE cable to the onboard RJ 45 conne...

Page 27: ...el installed 6 To complete the installation turn on the server 3 5 Starting the server l Turning on the power 3 5 1 Turning on the power To turn on the server 1 Press the power button on the front panel of the server 2 Wait for the power light to become solid green ATTENTION If the power light does not become solid green refer to the Troubleshooting section in the Dell PowerEdge T130 Systems Owner...

Page 28: ...w of Dell T130 The following image illustrates the front view of the Dell T130 server for MZ PCSV74 This server is provided with 3 5 inch Hot swappable hard drive chassis Figure 4 1 Front panel with 3 5 inch Hot swappable hard drive chassis The following are the explanation for the items in the images 28 CHAPTER 4 ...

Page 29: ...e Dell T130 server The following are the explanation for the items in the image 1 USB Connectors 6 2 Ethernet Connectors 2 3 System Identification Button 4 System Identification Connector 5 Video Connector 6 Power Supply 7 Self diagnostic Button 8 AC Power Supply Status Indicator 9 Serial Connector 10 Cooling Fan 11 VFlash 12 Ethernet Connector 1 13 Expansion Card Slots 4 29 Chapter 4 Operation ...

Page 30: ...on Connect the MAU to both Cable A and Cable B coax T connector as illustrated in the following Figure Figure 4 2 Connect the MAU to Cable A and Cable B 4 2 3 ControlNet Network A ControlNet Network is a single coaxial trunk cable broken up into segments interconnected by links Node Connections to the network are created through a Tap and drop cable Repeaters are used to link segments together and...

Page 31: ...available at the following Honeywell Process Solutions support website https www honeywellprocess com library support Documents Experion Magma_Installation_ Instructions_HWDOC X279 en pdf 4 3 Configuring ControlNet interface card You can configure a ControlNet interface card using the Magma PE3R PCie to PCI converter box 1 For more information on the Magma PE3R PCie to PCI converter box log into h...

Page 32: ...on Solutions support website before installing the third party hardware cards inside Magma chassis https www honeywellprocess com library support Documents Experion Magma_Installation_ Instructions_HWDOC X279 en pdf 32 ...

Page 33: ...r supply l Troubleshooting 5 1 Removing the Side Cover To remove or installs the components on the motherboard you must first remove the side cover 5 1 1 To remove the side cover 1 Press the release latch on the side cover and lift it up as shown in the below figure 33 CHAPTER 5 ...

Page 34: ...ard disk drive at a time in a system that is turned on Refer to the Dell documentation for detailed instructions on swapping the power supply and hard disk drive 5 2 1 References The following table lists the specific Dell publications and relevant sections for troubleshooting and servicing the hard disk drives and power supplies Publication Contains information about Dell PowerEdge T130 Systems O...

Page 35: ...IC adapter cards and SCSI controller cards Store and transport parts only in electro statically safe containers l Slot requirements for General Ethernet and FTE node setup 5 3 1 Slot requirements for General Ethernet and FTE node setup The following table identifies the specific slots for each of the Honeywell options for general Ethernet and FTE node configurations Configuration PCIe x 8 CPU PCIe...

Page 36: ...les from the server CAUTION The DIMMs are hot to the touch for some time after the system is powered down Allow time for the DIMMs to cool before handling them Handle the DIMMs by the edges and avoid touching DIMM components 5 4 2 To add additional memory 1 Remove the side cover of the server Refer to the section Removing the Side Cover 2 The DIMM memory sockets are now exposed 3 While wearing a g...

Page 37: ...ock the memory module into the socket When the memory module is properly seated in the socket the socket ejectors on the memory module socket align with the socket ejectors on the other sockets that have memory modules installed 7 Place the shroud back into the chassis and ensure that it is placed completely inside the chassis 8 Close the side cover 9 Replace the server in the cabinet 10 Connect t...

Page 38: ... 20 seconds 3 Remove the front bezel Refer to the section Removing the front bezel 4 Remove the side cover of the server Refer to the section Removing the side cover 5 Press the release latch on the side panel and lift it up as shown in the below figure 6 Locate the slot 1 7 Remove the metal shield in slot 1 38 Chapter 5 Servicing ...

Page 39: ...tly insert it in slot 1 9 Align the Magma PCIe host card edge with the card edge guide 10 Replace the card retainers blue plastic notch to lock the inserted Magma PCIe host card in position 11 Connect the Magma host cable to the Magma PCIe host card inserted in slot 1 12 Replace the side cover and the front bezel 39 ...

Page 40: ...nboard NICs marked as NIC1 and NIC2 l Entering the BIOS l BIOS settings for Tab 51156307 100 l Exiting the BIOS 5 6 1 Entering the BIOS To enter the BIOS 1 Turn on the server 2 Press F2 on the keyboard to enter the BIOS Setup 3 Verify that the BIOS version 5 6 2 BIOS settings for Tab 51156307 100 System information Product name Dell PowerEdge T130 server System model name T130 001 BIOS Version 1 2...

Page 41: ...em memory testing Disabled Memory operating mode Optimizer Mode CPU information Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Configurable TDP Nominal X2APIC Mode Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed 3 0 GHz 41 ...

Page 42: ...rcocode 0x74 SATA settings Embedded SATA AHCI mode Security Freeze lock Enabled Write cache Disabled PORT A Model HDD Model No Device type Hard Drive Capacity 500 GB PORT B C D Auto Model Unknown Device type Unknown device Capacity N A PORT E Auto Model Refer to DVD drive model number Device type Optical drive Capacity N A 42 Chapter 5 Servicing ...

Page 43: ...drive C 2 Embedded SATA Port Optical Drive E DVD drive model number 3 Integrated NIC1 Port 1 Partition1 BRCM MBA Slot 0100 v16 4 3 or higher Hard disk drive sequence Embedded SATA Port disk A HDD Model Number Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled Embedded NIC3 and NIC4 Enabled Embedded Video Controller Enabled Current state of...

Page 44: ...Slot 4 Enabled Serial communication Serial communication On without Console Redirection Serial Port Address Serial Device 1 COM1 Serial Device 2 COM2 External Serial Connector Serial Device 1 Fail Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled 44 Chapter 5 Servicing ...

Page 45: ...Management Maximum Performance Memory Frequency Maximum Performance Tubo boost Enabled C1E Disabled C states Disabled Memory refresh rate 1x Uncore Frequency Maximum Energy efficient policy Performance Number of Turbo boost enabled cores for processor 1 All Monitor Mwait Enabled 45 ...

Page 46: ...resent TPM Status Unknown TPM Command None Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Off AC power recover delay Immediate User defined delay 60s to 240s 60 UEFI Variable Access Standard Secure boot Secure boot Disabled Secure boot policy Standard Secure boot policy summary Secure boot Custom policy setting 46 Chapter 5 Servicing ...

Page 47: ...Option Rom Disabled 5 6 3 BIOS settings for Tab 51156307 200 System information Product name Dell PowerEdge T130 server BIOS Version 1 4 5 or higher System management Engine version 4 0 3 75 or higher Service Tag XXXXXX System manufacturer Dell System Manufacturer Contact info www dell com System CPLD version 1 0 0 or higher UEFI Compliance Version 2 4 or higher 47 ...

Page 48: ...isabled Memory operating mode Optimizer Mode CPU information Virtualization technology Enabled Adjacent cache prefetcher Enabled Hardware prefetcher Enabled DCU Steamer Prefetcher Enabled DCU IP Prefetcher Enabled Configurable TDP Nominal X2APIC Mode Disabled Number of Cores per processor All Processor 64 bit Support Yes Processor Core Speed 3 0 GHz 48 Chapter 5 Servicing ...

Page 49: ...r of cores 4 Mircocode 0 x 9c or higher SATA settings Embedded SATA AHCI mode Security Freeze lock Enabled Write cache Disabled PORT A Model HDD Model No Device type Hard Drive Capacity 500 GB PORT B C D Auto Model Unknown Drive type Unknown device Capacity N A PORT E Auto Model Refer to DVD drive model number Device type Optical drive Capacity N A 49 ...

Page 50: ...ATA Port Optical Drive E DVD drive model number 3 Integrated NIC1 Port 1 Partition1 BRCM MBA Slot 0100 v16 4 3 or higher Hard disk drive sequence Embedded SATA Port disk A HDD Model Number Integrated devices User Accessible USB Ports All Ports On Internal USB Port On Embedded NIC1 and NIC2 Enabled Embedded NIC3 and NIC4 Enabled Embedded Video Controller Enabled Current state of embedded Video cont...

Page 51: ...bled Slot 3 Enabled Slot 4 Enabled Serial communication Serial communication On without Console Redirection Serial Port Address Serial Device 1 COM1 Serial Device 2 COM2 External Serial Connector Serial Device 1 Fail Safe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled 51 ...

Page 52: ...erformance Memory Frequency Maximum Performance Tubo boost Enabled C1E Disabled C states Disabled Memory refresh rate 1x Uncore Frequency Maximum Energy efficient policy Performance Number of Turbo boost enabled cores for processor 1 All Monitor Mwait Enabled 52 Chapter 5 Servicing ...

Page 53: ...information NO TPM present TPM Status Unknown TPM Command None Intel TXT Off Power Button Enabled NMI Button Disable AC Power Recovery Off AC power recover delay Immediate User defined delay 60s to 240s 60 UEFI Variable Access Standard Secure boot Secure boot Disabled Secure boot policy Standard Secure boot policy summary Secure boot Custom policy setting 53 ...

Page 54: ...xit A confirmation message appears 2 Click Yes 5 7 Spare parts Item Description Dell part number Honeywell part number Expansion Ram 4 GB ECC DDR4 UDIMM 2133 Mhz or better 370 ACFU 51156061 901 Hard Disk Drive 500 GB 7 2K RPM SATA 3 Gbps 3 5 inch Hot plug Hard Drive or better 400 AEGM 51156307 901 SMPS Energy Smart Single cabled 290 W PSU 51156307 902 DVD Drive DVD RW SATA Internal 429 AAQL 511563...

Page 55: ...nying the product in the documents or files accompanying such third party materials in a file named third_ party_licenses on the media containing the product or at http www honeywell com ps thirdpartylicenses Documentation feedback You can find the most up to date documents on the Honeywell Process Solutions support website at http www honeywellprocess com support If you have comments about Honeyw...

Page 56: ...ell Process Solutions Customer Contact Center CCC To find your local CCC visit the website https www honeywellprocess com en US contact us customer support contacts Pages default aspx Training classes Honeywell holds technical training classes that are taught by process control systems experts For more information about these classes contact your Honeywell representative or see http www automation...

Reviews: